Electric installation (ECOFLEX EL, SL)
Convector is equipped by 3 conductors power supply cable (A05VVF) .
Power supply - 1/ N 230V / 50Hz
Colour indication of wires:
Phase - brown
Neutral - blue
Pilot wire - black
The power supply cable is connected to the wall
junction box.(Picture No.6). If not used, the pilot wire
must be connected to a potential free terminal in the
wall junction box. The power supply cable can only
be replaced by the manufacturer or an approved services company,as specific tools are
required.
Connection of pilot wire
The convector will operate according to the signals given
by the programmation device.
Tablet of signals. (ECOFLEX EL)
Control (ECOFLEX EL)
Description (Picture No.7).
ON/ OFF switch
Position"A" - heating off
Position"M" - heating on
A thermostat control knob,continuously variable setting
range from position * to position 9.
Heating indicator light (ECOFLEX EL)
Limiting or blocking the thermostat knob.(Picture No.8)
(ECOFLEX EL, SL)
There are detachable latches in the holes of thermostat
control knob,which are used to limit thermostat control
knob set point or is possible to limit knob between two
set points. (Setting a temperature range).
Limitation to a maximum temperature (ECOFLEX EL, SL)
Switch off the unit.Release convector from mounting bracket.Release one latch. Turn the thermostat
control knob precisely on the desired maximum temperature. Correctly screw latch in the hole
GB
indicated by the index"M". Return the knob to the position *. The knob should turn freely.
6
mounting bracket
power supply cable
pict. 6
Mode
Signal
Comfort
0
Eco
0
pict. 7
A M
7
pict. 8
F
M
wall juction
box