Reading SENSORS/BOILER SETTINGS (when
OTBus connection available between WiFi Box
EN InFO
and the boiler and if the OTBus allow it). Press
again the PROG (2) to enter on lower menu and
proceed to read the values available.
DE
Beschreibung
Description
16
Untermenü
Lower menu
They are shown in sequence the followings info
(if value not available "- -" is shown):
tSEt = set-point flow temperature calculated by
the thermostat.
tFLO = reading of the boiler flow sensor
temperature.
trEt = reading of the boiler return sensor
temperature.
tdH = reading of the boiler DHW sensor
temperature.
tFLU = reading of the boiler flues sensor
temperature.
tESt = reading of the boiler outdoor sensor
temperature (fitted to the boiler or communicated
by the web).
MOdU = instantaneous percentage of
modulation of boiler fan.
FLOr = instantaneous domestic hot water flow
rate.
HOUr = hours worked in high condensation
mode.
PrES = central heating system pressure.
tFL2 = reading of the heating flow sensor on
second circuit
EN