Herunterladen Inhalt Inhalt Diese Seite drucken

Using For The First Time; Recommendations; How To Drain The Dosatron; Fitting The Suction Tube - dosatron D 15 F 2 Gebrauchsanweisung

1.5 m3 /h - 7 gpm
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
Putting the Dosatron
into order

USING FOR THE FIRST TIME

- Open the water inlet valve slowly, the DOSATRON is self-priming.
- Operate the DOSATRON until the product to be injected is drawn up into the
injection stem (the product is visible through the plastic tube).
- The DOSATRON makes a characteristic "click-clack" noise when working.
NOTE: The time required to prime the suction hose depends on the water
flow-rate, the ratio setting and the length of the suction hose. To bleed the
air from the suction hose and accelerate the priming, set the injection rate
at maximum. Once the DOSATRON is primed, adjust to the required injec-
tion rate (see § ADJUSTING THE INJECTION RATE).
Maintenance

RECOMMENDATIONS

1 - When using soluble products to
be made up into solutions, we recom-
mend periodically dismantling of the
entire injection part
(see : § CLEANING
AND REFITTING THE
SUCTION VALVE
§ CHANGING SEALS IN
THE INJECTION ASSEMBLY).
Thoroughly rinsing all the ele-
ments of the injection part
with water and re-assembling
them after having previously
lubricated the seal (Fig. 7)
with a silicone lubricant, in the
case of difficulty in re-fitting.
©
DOSATRON INTERNATIONAL / 40
2 - Before putting the DOSATRON into
operation after a non-use period,
remove the motor piston and soak it
into lukewarm water <
40° C overnight. This
helps to dissolve any
deposits which may
have dried onto the
motor piston.
Seal
Fig. 7

HOW TO DRAIN THE DOSATRON

(In case of freezing temperature)
- Turn off the water supply.
- Remove the injection assembly, see
§ CHANGING THE MOTOR PISTON.
- Remove the top cap and the motor
piston.
- Disconnect the water inlet and out-
let fittings.
- Remove the pump body from the
wall support, unscrew the top cap
and empty any remaining water.
- The DOSATRON can now be reas-
sembled, having first cleaned the
seal (Fig. 8-N).

FITTING THE SUCTION TUBE

If the DOSATRON has already been
used, please imperatively refer to:
PRECAUTIONS.
- Unscrew the nut (Fig. 9-E) at the
bottom of the injection assembly
and put it onto the tube.
- Push the tube onto the barbed fit-
ting as far as it will go and screw up
the nut by hand.
- Identical process for viscous pro-
ducts option (Fig. 10-E).
Model in the drawing : D 200 RE
©
DOSATRON INTERNATIONAL / 41
N
Water
Water
inlet
outlet
Fig. 8
E
E
Fig. 9
Fig. 10
ø 6
ø 12
(option V)

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

D100rD 15 f 3D128rD 310 reD 200 re ieD 400 re ... Alle anzeigen

Inhaltsverzeichnis