• This product is for use indoors.
• A mounting bracket compliant with VESA specifications is
required.
• Since the monitor is heavy, consult your dealer before
installing, removing or moving the monitor.
• Mounting the monitor on the wall requires special expertise
and the work must be performed by an authorized SHARP
dealer. You should never attempt to perform any of this
work yourself. Our company will bear no responsibility
for accidents or injuries caused by improper mounting or
mishandling.
• Use the monitor with the surface perpendicular to a level
surface. If necessary, the monitor may be tilted up to 20
degrees upward or downward.
• This monitor should be used at an ambient temperature
between 32°F (0°C) and 104°F (40°C).
Provide enough space around the monitor to prevent heat
from accumulating inside.
For the monitor in landscape orientation
7-7/8 [200]
2
[50]
2 [50]
For the monitor in portrait orientation
7-7/8 [200]
2
[50]
2 [50]
• If it is difficult to provide sufficient space for any reason
such as the installation of the monitor inside a housing or
of several units side-by-side, or if the ambient temperature
may be outside of the range of 32°F (0°C) to 104°F (40°C),
install a fan or take other measures to keep the ambient
temperature within the required range. When installing two
or more monitor units side-by-side, provide space of at
least 3/16 inch (5 mm) around them to prevent stress on
the adjacent unit or structure due to thermal expansion.
• Do not block any ventilation openings. If the temperature
inside the monitor rises, this could lead to a malfunction.
• Do not place the monitor on a device which generates heat.

MOUNTING PRECAUTIONS

Unit: inch [mm]
2
[50]
5/16 [7]
Unit: inch [mm]
5/16 [7]
Power LED
2
[50]
• Adhere to the following when installing the monitor in its
portrait orientation. Failing to adhere to the following may
cause malfunctions.
- Install the monitor such that the power LED is located on
the top side.
- Set the THERMAL SENSOR SETTING on the SETUP
menu to PORTRAIT. (See OPERATION MANUAL.)
- Be sure to clamp the power cord (supplied) by using the
supplied cable clamp (affixing type). When clamping the
power cord, take care not to stress the terminal of the
power cord. Do not bend the power cord excessively.
Flat installation
• When using the monitor laying flat on a surface (when the
monitor is tilted 20 degrees or more upward or downward
from the perpendicular in relation to a level surface),
consult an authorized SHARP dealer because there are
some specific mounting conditions. Adhere to the following.
Failing to adhere to the following may cause malfunctions.
- Set THERMAL SENSOR SETTING in the monitor setting
menu to FACE UP or FACE DOWN. (See OPERATION
MANUAL.)
- Use the monitor at the ambient temperature within the
range of 32°F (0°C) to 86°F (30°C). Provide 7-7/8 inch (200
mm) or more space between the monitor and the ceiling
or other mounting surfaces and surrounding objects to
prevent heat from accumulating inside. If it is difficult to
provide sufficient space or if the ambient temperature
may be outside of the range of 32°F (0°C) to 86°F (30°C),
install a fan or take other measures to keep the ambient
temperature within the required range.
- Do not press hard on the LCD panel or otherwise subject
it to impacts.
Flat installation (FACE UP)
7-7/8 [200]
7-7/8
[200]
7-7/8 [200]
Flat installation (FACE DOWN)
7-7/8 [200]
7-7/8
[200]
7-7/8 [200]
Unit: inch [mm]
7-7/8
[200]
7-7/8
[200]
Unit: inch [mm]
7-7/8
7-7/8
[200]
[200]
5
E

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pn-y556Pn-y436Pn-y496

Inhaltsverzeichnis