Dismantling: (figure 6)
Follow the safety instructions.
Remove the plug from the socket.
Take the suction basket (2 – if present) out of the pump housing (3).
Remove the screws (12) from the non-return ring (11).
Take the entire pump (9) and the pump housing (3) out of the shaft
(10).
Remove the pump housing screws (8).
Take the pump housing (3) off the motor housing (9).
Take the rotor (5) out of the motor (9).
WARNING: The magnetic field of the rotor (3) is very
powerful and it will want to spring back into the motor
(9); you could be injured if you do not pay attention!
Pay attention to the o-ring (4).
Clean all parts with clean water and a soft sponge.
Replace broken/damaged parts.
Assembly: (figure 6)
Put the rotor (5) back into the motor (9).
WARNING: the magnet is very powerful and it will jump
back into the motor with some force. You could be
injured if you do not pay attention!
Replace the o-ring (4) and check to ensure this is positioned properly.
Check to ensure that the rotor (5) can turn around.
Replace the pump housing (3) on the motor (9) and then secure evenly
using the pumping house screws (8).
Place the motor (9) with the pump housing (3) back into the shaft (10).
Replace the non-return ring (11) and fix them in place using the screws
(12).
Place the suction basket (2) back on the pump housing (3) if the suction
basket (2) is being used.
Once everything is assembled, the pump can be switched on again.
Maintenance
To ensure a long life and problem-free operation, we recommend that you
maintain and clean your pump regularly. Maintenance work can be carried out by
anyone with very little effort, see also assembly/dismantling.
Time intervals:
In the beginning, you can check that the pump is working properly every
day. Clean the pump as set out above.
The regularity with which you clean the pump depends on the extent to
which the water is contaminated.
Check during maintenance to see if there has been any wear and tear or if parts
are worn or damaged. Replace any parts that are worn or damaged. Check the
list of replacement parts for this purpose. Important: If you have hard water
in your area, it is useful to regularly clean the rotor (5) and the interior
of the motor (9).