Herunterladen Diese Seite drucken

Renkforce 1227482 Bedienungsanleitung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G Operating Instructions
Door and window alarm
Item no. 1227482
Intended use
The product is used as a surveillance device for doors and windows. When the door
or the window is opened, a magnetic contact triggers the alarm, and the device emits
an audible alarm.
The time between the activation of the magnetic contact and the alarm can adjusted
(0, 10 or 20 seconds).
The alarm can be stopped at an early stage by entering a 4-digit password (changeable).
The product is powered by batteries.
Always observe the safety instructions and all other information included in these op-
erating instructions.
Any use other than that described above could lead to damage to this product and
involves the risk of short circuits, fire, electric shock, etc.
This product complies with the applicable national and European requirements. All
names of companies and products are the trademarks of the respective owners. All
rights reserved.
Package contents
• Door/window alarm
• Magnet
• 3 coin cells (type "LR44")
• Operating instructions
Explanation of symbols
This symbol indicates specific risks associated with handling, function and
use.
The "arrow" symbol indicates special tips and operating information.
Safety Instructions
D amages due to failure to follow these operating instructions will void the
warranty! We do not assume any liability for any resulting damage!
W e do not assume any liability for material and personal damage caused
by improper use or non-compliance with the safety instructions. In such
cases, the warranty will be null and void.
a) General
• Unauthorised conversion and/or modification of the product is not al-
lowed for safety and approval reasons (CE).
• The product is not a toy and does not belong in the hands of children!
Children do not realise the danger arising from the incorrect use of elec-
trical devices. In addition, the product contains small parts and batteries.
Therefore, be especially careful when children are around!
• Do not leave packaging material carelessly lying around, since it could
become a dangerous plaything for children.
• If you have any questions that are not answered in these operating in-
structions, please contact our technical service or another specialist.
b) Installation, connection and operation
• This product must be installed and used only in dry conditions indoors.
The product must not get damp or wet.
• Do not use the product in rooms that are under adverse environmental
conditions, where combustible gases, vapours or dust are or may be
present! There is a risk of explosion!
• The product must not be exposed to extreme temperatures, strong vibra-
tions or heavy mechanical stress.
• The product is suitable for use only in moderate climates, not tropical cli-
mates.
• The product emits a loud alarm sound when activated. In many countries,
there are restrictions with regard to volume and alarm duration. Please
follow any local regulations.
Battery instructions
• Batteries should be kept out of the reach of children.
• Do not leave batteries lying around in the open; there is a risk of them being swal-
lowed by children or pets. If they are swallowed, consult a doctor immediately.
• Leaking or damaged batteries can lead to caustic burning of the skin. Therefore, use
suitable protective gloves.
• Liquids leaking from batteries are very chemically aggressive. Objects or surfaces
coming into contact with these liquids might be considerably damaged. Therefore,
store batteries in a suitable location.
• Batteries must not be short-circuited, opened or thrown into a fire. There is a risk of
explosion!
• Do not recharge standard, non-rechargeable batteries, danger of explosion!
• Do not mix batteries with different charges (e.g. flat and half-discharged batteries).
• Always replace the entire set of batteries.
• Please pay attention to the correct polarity (plus/+ and minus/-) when inserting the
batteries.
Inserting/replacing the batteries
• Open the battery compartment on the front of the door/
window alarm by unscrewing the single attachment
screw of the battery compartment cover. Afterwards,
the battery compartment cover can be pushed down-
wards, in the direction of the arrow.
• Insert three batteries of type "LR44" with correct polar-
ity (observe plus/+ and minus/-).
The plus pole has to point outward, towards you; see the
illustration to the right.
• Slide the battery compartment cover back on and reat-
tach the screw that you removed in the first step.
• The batteries require changing when the volume of door/window alarm is very low
or no longer functions at all. Furthermore, the LED briefly lights up every 3 seconds
when the batteries are weak.
Installation
The door/window alarm and the magnet can be stuck
onto an even, clean surface that is free of grease
and dust. Remove the protective film on the back
and press the door/window alarm and the magnet
firmly down.
The magnet can be mounted either to the left or
right of the door/window alarm.
The distance between the magnetic contact in the
door/window alarm and the magnet should not be
more than 5 mm in order to ensure a safe function.
A height offset is not permitted.
One of the arrows of the magnet has to point di-
rectly at the arrow to the left or right of the door/
window alarm. See illustration on the right.
<5 mm
<5 mm

Werbung

loading