Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation - Duravit Paiova 5 Montageanleitung

Whirlwanne mit angeformter acrylverkleidung
Vorschau ausblenden Andere Handbücher für Paiova 5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Electrical installation

Power supply
Fuse protection
RCD
Pre-installation
> Installing a permanent power supply line:
Pre-connect a separate fuse and residual current
operating device (RCD)
Pre-connect an all-pole separating main switch
outside the prescribed safety areas (0 - 2)
Allow the supply line to protrude by 3,000 mm
> Laying the potential equalisation cable:
Allow the cable to protrude by 3,000 mm
18
Connecting the whirltub (Diagram 18)
NOTE! Avoiding any malfunctions!
Do not fasten the cables together with cable ties.
Do not install the supply line parallel to the control
cables.
I
Connect the supply line to the mains supply
socket.
II
Connect the potential equalisation cable to the
whirltub.
76xxxx xx x xx xx00: 50 Hz, 220 - 240 V AC
76xxxx xx x xx xx06: 60 Hz, 220 - 240 V AC
I
= 16 A
N
I
≤ 30 mA
∆N
0
6 0
1
0
I
L
N
PE
II
6 0
0
2
* or the height of
the highest shower
head / water outlet
that is permanently
installed; depending
on which is higher
WH_M_Paiova 5_integrated panel/15.01.1
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis