Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Sound-control:
Maximum ambient temperature T
Maximum housing temperature T
Minimum distance from flammable surfaces:
Minimum distance to lighted object:
Fuse:
Number of 5mm LEDs:
LED beam angle:
Dimensions (LxWxH):
Weight:
Please note: Every information is subject to change without prior notice. 29.01.2009 ©
230 V AC, 50 Hz ~
15 W
via built-in microphone
:
45° C
a
(steady state):
60° C
B
0.5 m
0.1 m
F 1 A, 250 V
66 RGB
60°
360 x 275 x 360 mm
3 kg