Spezifikationen
ethernet
ethernet mac show
ethernet link show
ethernet phyprefer set {10MBIT_HD=0|
10MBIT_FD=1|100MBIT_HD=2|100MBIT_FD=3}
ethernet phyprefer show
extsensor
extsensor {port_num} {TEMP=0|HYGRO=1} value
show
extsensor {port_num} {TEMP=0|HYGRO=1} label
set "{name}"
extsensor {port_num} {TEMP=0|HYGRO=1} label
show
extsensor {port_num} name show
extsensor {port_num} {TEMP=0|HYGRO=1}
events set {off=0|on=1}
extsensor {port_num} {TEMP=0|HYGRO=1}
events show
extsensor {port_num} {TEMP=0|HYGRO=1}
events type set
"{EVT_SYSLOG=0,EVT_SNMP=1,EVT_EMAIL=2,E
VT_SMS=3,EVT_GSMEMAIL=4,EVT_BEEPER=5}"
extsensor {port_num} {TEMP=0|HYGRO=1}
events type show
extsensor {port_num} {TEMP=0|HYGRO=1}
maxval set {num}
extsensor {port_num} {TEMP=0|HYGRO=1}
maxval show
extsensor {port_num} {TEMP=0|HYGRO=1} minval
set {num}
extsensor {port_num} {TEMP=0|HYGRO=1} minval
show
extsensor {port_num} {TEMP=0|HYGRO=1} hyst
set {num}
extsensor {port_num} {TEMP=0|HYGRO=1} hyst
show
extsensor {port_num} {TEMP=0|HYGRO=1}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port set {port_num}
extsensor {port_num} {TEMP=0|HYGRO=1}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} port show
extsensor {port_num} {TEMP=0|HYGRO=1}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state set {OFF=0|ON=1|
DISABLED=2}
extsensor {port_num} {TEMP=0|HYGRO=1}
{BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2|
BELOWMAX=3} state show
extsensor period set {24H=0|12H=1|2H=2|1H=3|
30MIN=4}
extsensor period show
extsensor display set {CURRENT=0|TEMP1=1|
HYGRO1=2|TEMP2=3|HYGRO2=4}
extsensor display show
http
http server set {HTTP_BOTH=0|HTTPS_ONLY=1|
HTTP_ONLY=2}
http server show
http port set {ip_port}
http port show
http portssl set {ip_port}
75
Expert Power Control 1202/1292
enters cmd group "ethernet"
show s MAC address
show s ethernet link state
sets preferred speed for PHY Auto Negotiation
show s preferred speed for PHY Auto Negotiati-
on
enters cmd group "extsensor"
show s sensor value
sets sensor name to label
show s label of sensor
show s type of sensor
enables sensor events on/off
show s if sensor events are enabled
enables different event types
show s w hat event types are enabled
sets maximum value for sensor
show s maximum value for sensor
sets minimum value for sensor
show s minimum value for sensor
sets hysterese value for sensor
show s hysterese value for sensor
sets Port for Pow er Port Sw itching actions
show s Port for Pow er Port Sw itching actions
sets Port state for Pow er Port Sw itching actions
show s Port state for Pow er Port Sw itching acti-
ons
sets sensor Min/Max measurement period
show s sensor Min/Max measurement period
sets default display
show s state of default display
enters cmd group "http"
sets connection types the w ebserver accepts
show s w ebserver accepting connection types
sets http port
show s http port
sets https port
© 2017 Gude Analog- und Digitalsysteme GmbH