External combustion air connection
In order to feed the combustion air to the stove ex-
ternally via a pipe instead of from the room in which it
is installed, it is possible to screw a ∅125 mm com-
bustion air pipe to the back of the stove, at the bot-
tom. If the combustion air pipe installed is longer than
3m, calculations will have to be carried out to verify
an adequate supply of combustion air. Use the Ols-
berg – combustion air pipes with sealing lip.

Installing the stove

The floor on which the stove is installed must be
even and horizontal. The stove may only be installed
on an adequate load-bearing floor. The stove can be
stood on a metal floor sheet or glass sheet to protect
the flooring. If the flooring or carpet is inflammable, a
stable, heatproof base must be used. This must ex-
tend 50 cm to the front and 30 cm to each side be-
yond the edge of the combustion chamber opening.

Assembly sequence

The Ø 150 stovepipe connection can be installed
at the top or rear.
The stove is supplied ready for connection from
above. If you wish to connect it at the rear, the
following steps must be carried out to make the
necessary modifications:
Erase the cover on the back panel
-
Unscrew the cover at the back
-
Unscrew the sealing cap at the back. Use a
-
screwdriver to secure the screws through the
connection pipe from turning too.
Unscrew the connection pipe through the rear
-
hole.
After
successfully
-
cap/connection pipe close off the hole in the top
cover with the enclosed insertable cap.
Decide where the stove is to be installed. There
must be no objects made of combustible materi-
als within a distance of 80 cm of the stove's ra-
diation area, measured from the combustion
chamber's inspection glass, nor may any be
placed within this area subsequently.
Minimum distance from combustible or load-
bearing walls: Lateral 10 cm and rear: 12 cm
Install the pipe lining (provided on site) in the
chimney.The connection height can be individu-
ally specified for a top stovepipe connection,
however should not exceed 1.5 m from the con-
nector sleeve. For the rear stovepipe connection
heights please refer the "Technical Data" table.
No combustible material is permitted within a ra-
dius of 20cm around the stove pipe.
Place the stovepipe (provided on site) on the
Ø160/Ø150mm transition piece of the stove.
Push the stove onto its planned position and
orient it so that the stovepipe fits into the pipe lin-
ing.
changing
the
sealing
The stovepipe connections must be airtight. The
stovepipe must not protrude into the chimney.

Water Installation

Important:
The respective locally-applicable regulations and
rules must be observed.
The installation of water connections and all elec-
trical work must be completed by certified spe-
cialists.
We recommend using the following Olsberg
components for connecting the respective items
to the heating and/or industrial water system:
- Installation unit
- Temperature difference controller TDC1
Please follow the separate assembly and operation
instructions for these Olsberg components.
In addition to the requisite safety components, a
return flow booster valve must be installed, which
increases the return flow temperature to at least
55°C. (the Olsberg installation unit includes such
a valve).
The stove must never be operated without water.
The oven must never be operated without a cor-
rectly-installed and functional thermal discharge
safety device (TAS).
An outlet valve must be installed in the lower
section of the water circulation system.
Thermal discharge safety device
(TAS)
The TAS inlet must be connected to the building's
cold water system; water from the TAS outlet must
be allowed to flow directly into the drain.
The TAS must prevent the heater from overheating
when the heat being generated cannot be removed
by the water. Overheating would cause impermissibly
high temperatures and pressures which would result
in irreparable consequences for the wood heater. In
order to prevent this, the TAS' safety valve will open
depending on the water temperature in the wood
heater's heat exchanger (TAS sensor pocket) to al-
low cold tap water to remove the heat.
Do not add any more wood in the event of any such
malfunctioning.