Problem
Burner does not switch
off
Room thermostat
switches burner off
before the desired room
temperature has been
reached
Ventilator does not start
up
If the device is being supplied with power through the mains cable, work on the
electrical unit can only be carried out by specialist electricians and/or a person
trained in this area in accordance with VBG 4.
Please only get repair work to the electrical, gas and oil connections for fan-assisted air heaters
done by HEYLO service partners.
Placing the device out of operation and disposal
The device is designed for long term operation.
If it is to be disposed of, this must be done in accordance with the current relevant legal
regulations in an environment friendly manner.
Any more questions? We would be glad to help!
Your HEYLO customer service:
Tel.
+49 (0) 42 02 – 97 55 15
Fax
+49 (0) 42 02 – 97 55 97
Email service@heylo.de
Possible cause
Combustion air is not properly
set
Room thermostat has been
fitted in an inappropriate place.
Defective room thermostat
The room thermostat has been
fitted to a place where it comes
into contact with hot air or rays
of heat, e.g. from the sun,
machines, hot water or steam
pipes.
Temperature regulator -1S3.1
(see wiring diagram) is not
functioning
No power supply
31
Solution
Adjust combustion air (can only be
done by an expert).
Fit the room thermostat at another
place. It is important, for proper
controlling, that the room
thermostat if fitted in the room to
be heated, should be fitted in such
a way that no flow of cold air from
windows, doors etc. comes into
contact with it. If appropriate, move
the room thermostat to another
place.
Examine the room thermostat (can
only be done by an expert),
change it in emergency cases.
Move the thermostat to another
place
Check, whether the temperature
regulator -1S3.1 is functioning, if
necessary it has to be exchanged.
Check the terminal strip X1 with a
voltage tester (see wiring diagram)
to see whether the ventilator drive
is being supplied with electricity.
Terminal 4 and 6N (see wiring