Mobile warm-air heaters
Type K 160 eco

1. General information

Equipment description

The K160eco lit with heating oil EL, is a compact fan-assisted air heater (WLE) that can be used
in many ways and is easy to transport for heating and drying. It functions equally well with and
without a chimney and, with its high heat capacity, it is compact and light, but still built as a
robust device. The WLE can only be used commercially.
Due to its innovative combustion technology and the highly efficient heat exchanger made of
stainless steel, the device belongs to the most economical of its kind.
Fan-assisted air heaters are intended for spot heating of repair areas in the open and in closed
rooms, for thawing and heating of machines, devices and pipelines and for drying of rooms, hay
and crops as well as auxiliary heating in emergency cases.
A tested oil burner has been installed in accordance with DIN EN 267. The current operating
instructions for the WLE will definitely be supplemented by the operating instructions of the
burner manufacturer for the burner.

Safety instructions

The equipment can only be operated by sufficiently trained persons.
Mobile fuel containers can only be installed and operated under observation of the Technical
Regulations for Combustible Fluids (TRbF 20).
Do not install and operate the equipment in oily, sulphurous or salty environments.
The equipment should not be exposed to sprayed water (e.g. high pressure cleaners).
Only WLE models of blower oil burners in accordance with DIN EN 230 and DIN EN 267 can be
used.
On no account can the safety facilities be blocked or bridged over.
The equipment can only be operated unsupervised with a thermostatic regulator.
Strictly speaking, the equipment should only be disconnected from the mains supply in a cooled
off state.
Equipment must be installed on level surfaces, ensuring that they are stable.