Mobile warm-air heaters
Type K 160 eco
Safety clearance
-
On the sides of combustible parts:
-
Blow-out side of combustible parts:
-
Suctioning-in side for free in-flow of air:
-
upwards:
Legal regulations
The following regulations must be observed during installation and start-up:
-
Arbeitsstättenverordnung (Health and Safety at Work Act) §§ 5 and 14
-
Arbeitsstättenrichtlinie ASR 5 (Health and Safety at Work directive)
-
Unfallverhütungsvorschriften VBG 43, VBG 21(Accident Prevention Regulations)
-
Feuerungsanlagenverordnung (FeuVo) (Ordinance for Combustion Equipment) of the
individual German states.
Available at: Deutsches Informationszentrum für technische Regeln (DITR) (German
Information Centre for Technical Regulations) at DIN,
Burggrafenstraße 6, 10787 Berlin

8. Maintenance

The device has to be maintained and cleaned at regular intervals to ensure operational safety
and maintenance of prescribed ecological limits as well as economic viability.
HEYLO recommends an interval of at least 12 months.
Maintenance work can only be carried out by competent experts. A fan-assisted air heater that
is always kept clean ensures good combustion with undisturbed operation and a long life.
PLEASE NOTE !! Pull out the mains plug first before doing any maintenance work!
1. The oil filter must be cleaned and the oil nozzle must be changed after every heating period
or sooner.
2. The internal parts must be cleaned thoroughly to remove dust and dirt after every heating
period or sooner, depending on how much dirt there is at the place of use.
3. Soot must be removed from the combustion chamber after every heating period and the
burners must be checked for flawless values (can only be carried out by a specialist).
4. Only use original spare parts.
There are 3 openings on the K 160eco to clean the heat exchanger. One is on the exhaust
gas nozzle and can be opened by removing the hood and loosening the screws on the flange.
The second and third openings for cleaning are on the blow-out and suctioning-in sides of the
heat exchanger. Please remove the maintenance covering for this purpose.
Adjustement thermostats
TL
performance thermostat
TW
temperature monitor
TR
temperature controller
0.60 m
2.00 m
0.60 m
3.00 m
70° C
80° C
35° C