Herunterladen Inhalt Inhalt Diese Seite drucken

Function Of The Pulse Output Out1; Funktion Des Pulsausgangs Out1 - Alcatel-Lucent BG 75 SI Betriebsanleitung

Ec-motor mit integriertem drehzahlregler
Inhaltsverzeichnis

Werbung

9.6 Function of the pulse output OUT1

The pulse output OUT1 provides 12 impulses per motor
turn, whereas the pulse duration t
t
is motor speed addicted. As a result of the generation
0
of the pulses via sampling, a fuzziness of up to 100 ms
arises at the flanks, so that a measurement of the pulse
duration larger than 1 pulse is not adequate for desi-
gnation of the motor speed. The pulse duration t
the pulse brake t
are at the same length on average.
0
Thereby, approximately following correlation is essenti-
al at a rotation of n rpm:
The output is performed as PNP-transistor 24 V plus
switching, with a max. permitted current strain of 250
mA.
Instruction Manual/Betriebsanleitung BG75SI, Version: 1.1 en_de
© 2008 Alcatel-Lucent; Dunkermotoren; D-79848 Bonndorf; Germany
and the pulse brake
P
and
P
t
= (2000 / n) ms
P
12 pulses comply with 1 motor rotation
12 Impulse entspricht 1 Motorumdrehung

9.6 Funktion des Pulsausgangs OUT1

Der Pulsausgang OUT1 liefert 12 Impulse pro Motor-
umdrehung, wobei die Pulsdauer t
spausendauer t
drehzahlabhängig ist. Aufgrund der
0
Erzeugung der Impulse durch Abtastung ergibt sich
bei den Flanken eine Unschärfe von bis zu 100 ms,
so dass eine Pulsdauermessung über 1 Impuls nicht
zur Drehzahlbestimmung geeignet ist. Die Pulsdauer
t
und die Pulspausendauer t
P
lang. Dabei gilt bei einer Umdrehungszahl von n rpm
ungefähr folgender Zusammenhang:
Der Ausgang ist als PNP-Transistor 24 V-plusschal-
tend mit einer max. zulässigen Strombebelastung von
250 mA ausgeführt.
9 Operation hints
9 Betriebshinweise
und die Pul-
P
sind im Mittel gleich
0
27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis