Operation mode "manual"

Display
manual
power:
4
off
Tu,08:55
next
manual
power:
4
heating
Tu,08:55
next
54
Action
Description
In "manual" mode the appliance heats in the preset
time programs depending on the selected power lev-
el.
Outside of the time programs the appliance is in
heating pause.
If no time programs are stored, continuous opera-
tion is possible.
The power level 1-5 can be set at any time:
- Power level 1 corresponds to 2.6 kW
- Power level 5 corresponds to 8.0 kW
Factory setting: 4
or
Select the power level with (ENTER) (the power lev-
el flashes), set the value with ↓ or ↑ and confirm with
(ENTER).
By pressing the "Fire-key" the heating release is is-
sued or blocked.
The party function is switched on with the "Party-
key", i.e. the preset time programs will de ignored
and the appliance heats with the set power level.
When switching on during the operating status "heat-
ing", the next "switch-off time" will be ignored, the
appliance continues to heat. At the following switch-
on time, the party function switches off automatical-
ly and the appliance again works as programmed.
When switching on during "standby" operating sta-
tus, the "switch-off time" that is taking place will be
ignored and the appliance ignites in order to go into
heating mode. At the next switch-on time the party
function switches off automatically and the appliance
again works as programmed.
By repeatedly pressing the "Party-key" the party
func tion can be switched off manually.
With the "cocktail glass" symbol the party function is
shown in the upper right of the display.