6 Specifi cations
6 Caractéristiques
Minimum Guaranteed Power, 1 kHz
Puissance minimum garantie, 1 kHz
Garantierte Mindestleistung, 1 kHz
Potencia Mínima garantizada, 1 kHz
Per channel, both channels driven
Par canal, les deux canaux pilotés
Pro Kanal, beide Kanäle in Betrieb
Por canal, ambos canales operando
Stereo, 2 ohms (per ch.)
Stereo, 4 ohms (per ch.)
Stereo, 8 ohms (per ch.)
Bridge-Mono, 4 ohms
Bridge-Mono, 8 ohms
With 0.5% THD.
*With 1% THD.
† Not rated for 100V versions.
Sensitivity (volts RMS) for full rated power at 4 ohms
Frequency Response (at 1 watt into 4 ohms,
20Hz - 20 kHz)
Signal to Noise Ratio (below rated 1 kHz power at 8
ohms), A-weighted
Damping Factor (8 ohm): 20 Hz to 400 Hz
Input Stage
AC Line Current
page 32
XTi Series Power Amplifi ers

6 Technische Daten

XTi
XTi 2000
XTi 4000
1000
700W*
1000W*
1600W*
500W
800W
1200W
275W
475W
650W
1400W*
2000W*
3200W*
1000W
1600W
2400W
1.4V
+0/–1 dB
100 dB
> 500
Input is electronically balanced and employs
pre cision 1% resistors.
XTi 1000: 6.5A, XTi 2000: 6.9A, XTi 4000: 8.0A.
At idle: Draws no more than 90 watts.
Operation Manual
Amplifi cateurs de puissance
6 Especifi caciones
Crosstalk (below rated power)
20 Hz to 1 kHz
Input Impedance (nominal)
Load impedance (note: safe with all types of
loads)
Stereo
Bridge mono
Voltage Gain (at 1 kHz, 8 ohm rated output)
Maximum Input Signal
Operating Temperature
AC Line Voltage and Frequency Confi gura-
tions Available (± 10%)
Ventilation
Cooling
Dimensions: Width, Height, Depth
(behind mounting surface)
Net Weight, Shipping Weight
Mode d'emploi
Leistungsendstufen
Amplifi cadores de potencia
> 70 dB
20 kilohms balanced, 10 kilohms unbalanced
2-8 ohms (4-8 ohms in XTi 1000 A1 100V versions)
4-16 ohms (8-16 ohms in XTi 1000 A1 100V versions)
XTi 1000: 30.5 dB. XTi 2000: 32.9 dB. XTi 4000: 34.2 dB
+22 dBu typical
0° C to 40° C at 95% relative humidity (non-condensing)
100V, 120V, 220-240V 50/60 Hz
Flow-through ventilation from front to back
Couler-à travers la ventilation de l'avant au dos
Luftstrom von Front zu Rückseite
Ventilación de circulación de fl ujo del frente hacia atrás
Heat sinks and proportional-speed fan
Radiateurs et ventilateurs à vitesse proportionnelle.
Wärmetauschern und Lüfter mit Proportionaldrehzahl15
Disipadores de calor y ventilador de velocidad proporcional
EIA Standard 19 in. W (EIA RS-310-B)
x 3.5 in. (8.9 cm) H x12.25 in. (31.1cm) D
Largeur de la norme 19 d'EIA (EIA RS-310-B)
EIA Standard 19" Breite (EIA RS-310-B)
Estándar EIA 19" de ancho (EIA RS-310-B)
18.5 lb (8.4 kg), 21.5 lb (9.8 kg)