INNOCIGS CUBOID PRO – ERROR MESSAGES & PROTECTIVE FUNCTIONS
Recharge Battery
If the voltage falls below 3.3 V, "BATTERY LOW" will appear on the display. When the Fire button is pressed again,
"BATTERY LOW LOCK" will appear and the device switches off. Please recharge the device.
Atomizer Low Alarm
If the resistance of the coil drops below 0.1 ohm in VW mode or below 0.05 ohm in TC or TCR mode, the display will
show "ATOMIZER LOW."
Temperature Protection
If, in TC/TCR mode, the actual temperature of the coil has reached the set temperature, "PROTECT" will be shown on the
display. You can continue to use the device as usual.
Temperature Alarm
If the temperature of the device rises above 70°C, it will switch off automatically and "DEVICE TOO HOT" will appear on the
display. You can continue vaping after the device has cooled down.
69