1. Nominal temperature setting
Confirm with the (Menu) key.
(+) set temperature
(-) set humid.
Set the required nominal temperature value with the (+) or (-) key. A range of values from
.0 to 9.0 °C is enabled. After the setting has been carried out the new values are
immediately saved.
2. Nominal moisture setting
Confirm with the (Menu) key.
(+) set temperature
(-) set humid.
Set the required nominal value with the (+) or (-) key. A range of values from 0 to 90 %
relative humidity is enabled. After the setting has been carried out the new values are
immediately saved.
Attention!
Air humidification only starts when the set temperature (+/- 0. °C) has been reached.

Operation

t: 37.7° set: 37.7°
h: 60%
set: 60%
t: 37.7° set: 37.7°
h: 60%
set: 60%
– 17 –
Confirm with the (+) key.
set point
temp.: 37.7 °
Confirm with the (-) key.
set point
humidity: 60 %rh