4.2

Light Emitting Diodes (LED)

LED
Marking
1
AC IN
2
CHARGER
SOLAR
3
CHARGE
4
Program
Contact
5
active
Contact
6
manual
7
TRANSFER
8
AC OUT
9
INVERTER
10
Over Temp.
11
Overload
Batt.
12
Low/High
13
OFF
14
EQUALIZE
15–18
LED lit
Voltage
corresponding to
self-adjusted
values is at the AC
IN input.
Battery charger is
working
This function is not offered for the Compact.
Program mode for
Aux. Contact
Auxiliary Contact is
activated
Aux. Cont.
manually activated
Transfer system is
active. In- coming
voltage is being
sent directly to AC
OUT outlet
There is a voltage
at the AC OUT
outlet
Inverter is working
For the time being
the COMPACT is
out of service
because of
overheating.
The COMPACT is
out of service
because of
overload or short-
circuit
Battery voltage is
too low
COMPACT is
turned off. Turning
it back on is only
possible manually.
Battery equalizing
is set
State of charge of
the battery
COMPACT V6.4
LED blinks
A voltage outside the self-adjusted
values is at the AC IN input, or the
COMPACT is in synchronization phases
The battery charger is locked OFF (see
chap. 4.6) or provisory out of order. In
that last case it will restart within 10
seconds
Transfer (bypass) is disabled (see chap.
4.7)
The Inverter is in Standby-Mode
Forced Inverter Mode (see chap. 4.5)
Battery voltage is or was to high
COMPACT is for the time being turned
off. Turning it back on will follow
automatically !
LED 15 – Absorption time is running
COMPACT