Wind
The SC211A detects any vibration in the awning and evaluates it.
The SC211A transmits this value to the receiver.
The receiver compares the value to the threshold (set using a transmitter such
as the SWC241A). If the value measured is above the threshold (wind alarm), the
folding-arm awning is retracted immediately.
If this happens, the awning cannot be extended for approx. 15 minutes.
Angle of inclination / Release angle
The SC211A detects a gradual increase or decrease in the awning's angle of
inclination relative to the initial angle of inclination e. g., due to rain (formation
of water pools). If the awning reaches the release angle, a retract command is
sent to the receiver.
The rotary switch is used to set the release angle between ± 1° and ± 9° in
1° increments.
The factory default is 0 (off).