SLS4K40– Installation and User Guide
Terminal assignment
Terminal
Connector
X1
Pin1
Pin2
X2...X5
Pin1
Pin2
X6
Pin1
Pin2
X7...X10
Pin1
Pin2
X11
Pin1
Pin2
Pin3
Pin4
Pin5
The light control SLS4K40 is intended for connection to a 12V power supply (DC) and/or 12V
battery. The power supply must have a sufficient current rating.
The light control SLS4K40 is protected against temporary pole reversal of the supply connections.
The outputs K1 to K4 are protected against excess temperatures, overload and short circuits.
Ongoing faulty operating states, such as pole reversal, short circuits or overload, should
nevertheless be avoided to prevent damage to the light control.
The light control SLS4K40 is not suitable for LED lamps with electronic ballast.
The cross-section of the cables must be suitable for the power consumption.
Cable assignment for "4-fach-Tastmodul"
"4-fach-Tastmodul" (X1)
LUMBERG Micromodul connector MICA 06
Function
L+
Power supply (external 10A fuse required!)
M
Tx
Button T1...T4
M
IO
Button COMING-HOME/ CENTRAL-OFF
M
Kx
Output channel 1...4
M
M
Four-button-keyboard (e.g. 4-fach-Tastmodul)
T1
Identical to X2.Pin1
T2
Identical to X3.Pin1
T3
Identical to X4.Pin1
T4
Identical to X5.Pin1
LED
X1.1
S1
X1.2
M
X1.3
S2
X1.4
S3
X1.5
S4
X1.6
SLS4K40 (X11)
LUMBERG Minimodul empty housing 3114 05
with 5 crimp contacts 3111
X11.1 M
X11.2 T1
X11.3 T2
X11.4 T3
X11.5 T4
Seite 11