Button functions
Button
Condition
T1...T4
Channel off
Channel on
IO
System off
System on
Button pressed long means for more than 0.8 seconds.
Only one button should be pressed. When pressing several buttons at the same time there is no reaction.
Operating modes
Mode
Description
Normal
System works without any limitations
Green LED is clocked at 1 Hz and 80% duty
Supply voltage < 11.0V
Reduced
Channels 1...4 can only be turned on to 50%
Green LED is clocked at 1 Hz and 50% duty
Supply voltage > 11.5V
Supply voltage < 10.0V
Emergency
Channel 1 can only be turned on to 30%; Channels 2...4 off
Pressing the buttons T2...T4 cause channel 1 to turn on
Green LED is clocked at 1 Hz and 20% duty
Supply voltage > 10.5V
Supply voltage < 9.0V
Shutdown
All channels are turned off
Green LED is off
If no button is pressed for 2 seconds the system switches into POWER-DOWN
Supply voltage > 9.5V
POWER-DOWN
System is turned off = minimal energy consumption
Green LED is off
Wait for pressed button
The accuracy of the supply voltage measurement is ± 0.3V.
Action
Button pressed
Button pressed shortly
Button pressed long
Button pressed
Button pressed
switching to Reduced
switching to Normal
switching to Emergency
switching to Reduced
switching to Shutdown
switching to Emergency
Reaction
Channel turned on to 100%
Channel turns off
Channel is dimmed:
After turning on the channel, the intensity is first reduced,
then the intensity is increased or reduced alternately when
the button is actuated again
COMING-HOME fixed values:
System turns off (POWER-DOWN)
Channel 1 = 30%
Channel 2...4 off