Indicator
Function
Colour
Power supply
red
Fault
yellow
Defrost
white
On/Off
red
Indicator
Function
Colour
Power supply
red
Fault
yellow
Defrost
white
On/Off
red
Indicator
Function
Colour
Mains supply
red
Fault
yellow
Defrost
white
On/Off
red
Indicator
Function
Colour
Mains supply
red
Fault
yellow
Defrost
white
On/Off
red
B - 5
Check list
Fan and compressor won't run
Status
Off
Check to ensure that the fuses for the supply cable are OK .
Off
Off
Check to ensure that the ON/OFF switch is ON (DH 150 only) .
Off
Fan is running, compressor is off
Status
On
Check to ensure if the dehumidifier's humidistat is switched on and that
the air temperature is not above the temperature setting of the humidistat .
Off
Check the internal fuses/safety switch .
Off
Check if the standby switch is switched to ON .
On
Status
On
Check to ensure that the air flow is not obstructed . Reset the high
pressure switch (only for DH 300 & DH 600) .
On
Check the overheat protection at the soft start and at the optional
heater .
Off
Off
Check the fan to see in which direction it rotates (only for DH 300
& DH 600) .
Status
On
Check if the air temperature is above 0°C (DH 150) and above
-15 °C (DH 300 & DH 600) .
Off
On
Please note: It is normal for the dehumidifier to switch automati-
On
cally to defrost mode once every hour .