Herunterladen Inhalt Inhalt Diese Seite drucken

Common Malfunctions - LIGHTMAX Shaft 5R Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

LightmaXX
Shaft 5R
Beam Moving Head
______

9. Common Malfunctions

1. Bulb cannot light up
A. Bulb con not cool down completely because of improper operation .First cool the fan inside the light body
do for about 10 minutes, then switch off the power, 5 minutes later, after all inner parts return to normal,
restart the power at last .
B. The inner temperature is overheated and become into overheat protection state .Check if the fan and air
hole stuck by sundries.
C .Check if the bulb has expired, if so, change to new one .
D. Check if it has leakage, detachment, or poor contact between the bulb an d trigger wire.
E. Check whether the fan speed is abnormal or damaged on the panel menu.
2. The beam becomes dim
A. The bulb may have expired, change it to new one.
B. Check if the optical parts are clean.
C. Keep routine maintenance to the bulb and other inner parts as the bulb accumulates dust.
3. Motor doesn't work
A. Check whether the power is suitable voltage and fuse is burnout.
B. Check whether the motor wire and connecting wire are ageing to broken.
C. Check whether the fastening flange screw is loose and stuck by other things.
D. Check whether the plug-in on the PCB and IC components is loose, poor connection or ageing burnout.
E. Check whether the power output voltage is normal.
4. Communion is out of control
A. Whether communication cable is incorrect linked, dry joint, loose or open circuit .
B. Whether the address code is set correctly.
C. the IC on the PCB has been high-voltage breakdown.
D. The connection line is too long to keep the signal enough. you can cascade the signal amplifier and equip
the"2","3" cannon plug of last light with one 1W/120Ω terminal resistance.
E. Interfered by peripheral equipment signal or voltage.
F. Controller has been damaged or signal is in-compatible.
5. The shadow casted has halo
A. Check whether the channel value of focusing is suitable for the projection distance.
6. The light works intermittently
A. Check whether the fan works abnormally or dusty.
30

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis