MIC440 Explosion Protected CCTV Camera System| Installation and Operation Manual
IMPORTANT SAFETY INSTRUCTIONS
1. Read and keep these instructions
2. Heed all warnings and Follow all instructions
3. Do not install near any strong heat sources such as furnaces
4. Do not back-drive the pan or tilt axis of the camera. To do so will damage
the motor drive gear chain and will invalidate the warranty
5. Do not use caustic or abrasive cleaning products on the unit
6. Do not point the MIC440 camera at the sun. BOSCH Group will not be liable
for any damages to cameras which have been directly pointed at the sun
7. In situations where there could be a risk of injury should any part of the
assembly become detached for any reason and fall, normal common sense
safety precautions should be employed; a strong safety chain between the
camera pan shaft and the mounting surface is recommended
8. For transportation please rotate the ball so the window points towards the
base, this helps to protect the wiper & windows during transit
9. Ensure that the product case is properly earthed. If the product is likely to
be struck by lightning, ensure that earth-bonding connections are made
correctly to the mounting base of the unit
10. Use only the power sources indicated in this user guide and ensure that the
current rating of supply cables, fuses and overload protection devices are
adequate for the product.
11. The product is certified for use within the ambient temperature range of
-20C to +60º C and must not be used outside this range.
12. This product must only be installed by suitably trained personnel in
accordance with the relevant code of practice (e.g. EN60079-14:1997).
These instructions are intended for their sole use.
13. All installation work should be carried out in accordance with the relevant
local and national standards.The unit shall only be installed and brought into
service using the operating parameters defined in these instructions and in
the technical specifications.
14. There are no user serviceable parts and on line maintenance is not required
for this product.
15. Inspection and maintenance of this equipment must be carried out by
suitably trained personnel in accordance with the applicable code of
practice e.g. EN 60079-17.
16. Repair of this equipment must be carried out by suitably trained personnel
in accordance with the applicable code of practice e.g. EN 60079-19.
17. Units must carry the following certification marking.
SIRA05ATEX1300X
Exd IIC T6 Ta –20ºC to +60ºC Gb
Bosch Security Systems
WARNING
NO REPAIRS REQUIRING OPENING THE PRODUCT
CASING WHILST IN A HAZARDOUS AREA ARE
ALLOWED.
FAILURE TO OBSERVE THIS PRECAUTION WILL VOID
THE CERTIFICATION AND WARRANTY.
BOSCH SECURITY SYSTEMS ACCEPTS NO LIABILITY
FOR LOSSES CAUSED BY INCORRECT INSTALLATION
OR MISUSE OF THE PRODUCT
Please contact BOSCH Security Systems for details of approved repair centres.
This product complies with the following EC directives:-
EMC Directive (89/336/EC as amended)
Machinery Directive (98/37/EC)
LV Directive (73/23/EC)
RoHS (Restriction of Hazardous Substances) 2002/95/EC
WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC
This equipment contains electrical or electronic
components that must be recycled properly to comply with
Directive 2002/96/EC of the European Union regarding the
disposal of waste electrical and electronic equipment
(WEEE). Contact your local supplier for procedures for
recycling this equipment.
This product is designed for use with flammable gases and vapors
covered by apparatus groups IIA, IIB and IIC and with temperature
classes T1 to T6.