Control lamp holder

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

In relation to device's voltage, make sure to follow safety
precautions during mounting:
1. Switch the light off.
2. Insert the motion sensor light bulb socket into any
existing ceiling bulb socket; then insert a light bulb into
the motion sensor light bulb socket.
3. Switch the light on.
4. The device enters normal work mode after about 40
seconds. After first installation the lamp may light on
and off several times during those 40 seconds (this is
normal phenomena).
5. The lamp will automatically turn the light on whenever
motion is detected (if the light intensity is not strong
enough).
6. When the movement is no longer present, the light will
be automatically switched off after previously preset
delay time (15-160 seconds).
7. Suitable installation height from floor: 2,5-3 m.
Adjustment knobs:
EN
8
– 10 Lux licht
Working brightness adjustment button: turn
anticlockwise to make the lamp work in weak
ambient light.
Time delay adjustment button: turn to adjust
switch off delay time (15-60 seconds).
Detection sensitivity adjustment button: turn
clockwise to strengthen the sensor sensitivity
and expand the detection distance range.
OWNER'S MANUAL
– Daylicht

Werbung

loading