• O­ring or seals cracked or broken.
• Replace O-ring/seals.
• Jammed fastener head.
• Check the piston, head valve spring.
• Trigger assembly worn/leaky.
• Replace trigger assembly.
• Dirt and grease accumulated in drive
assembly.
• Disassemble fastener head/drive assembly
and clean it.
• Cylinder case not correctly mounted on lower
piston.
• Disassemble, and reassemble correctly.
• Head valve dry.
• Disassemble and lubricate.
• Insufficient working pressure.
• Check the mains air supply / compressor.
8. Skipping nails, intermittent feed.
• Worn piston.
• Replace piston.
• Dirt and grease accumulated in drive
assembly.
• Disassemble fastener head/ drive assembly
and clean it.
• Restricted air supply, insufficient airflow
through coupling.
• Replace the quick-detachable the quick-
detachable coupling.
• Worn piston O­ring.
• Replace O-ring, check drive assembly.
• Machine is dry, insufficient lubrication.
• Apply lubricating oil for pneumatic tools.
• Damaged magazine feed pressure spring.
• Replace spring.
• Low air pressure.
• Check air supply to the tool.
• Fasteners too short for this tool.
• Only use specified fasteners.
• Bent fasteners.
• Cease using these fasteners.
• Incorrect size fasteners.
• Only use specified fasteners.
• Leaky head gasket.
• Tighten the screws / replace the gasket.
• Trigger valve O­ring cracked/worn.
• Replace O-ring.
• Broken drive pin.
• Replace the drive pin (check piston O-ring).
• Dry, dirty magazine.
• Clean, lubricate using oil for pneumatic
8
tools.
• Worn magazine.
• Replace the magazine.
• Fastener guide worn.
• Replace the magazine.
• Incorrect size fasteners.
• Only use specified fasteners of the correct
size.
• Bent fasteners.
• Cease using these fasteners.
• Broken drive pin.
• Replace the drive pin.
Working practice when preforming
maintenance
Whenever you are repairing the air nailer, take
care to clean and lubricate the internal parts. Use
Parker "O­Lube" or similar on all O­rings. Coat all
O­rings with O­Lube before reassembling.
Apply oil lightly to all moving surfaces and pins.
Finally, following complete assembly, squirt a few
drops of pneumatic tool lubricant into the air input
fitting, before commencing testing.
Air pressure and volume
Air volume is just as important as air pressure.
The air volume that is delivered to the air nailer
may be insufficient due to defective couplings
and crimped hoses, or through the effect of
contamination and water in the system.
The consequence of a restricted airflow is that
the air nailer receives an inadequate air volume,
even though the air pressure reading is high.
This will lead to defective operation, through
reduced driving power. Before you begin with
troubleshooting, you should first inspect the
path from compressor to air nailer for restricted
connections, twisted hoses and anything else that
might prevent sufficient air from flowing to the
appliance.
Lubrication
Frequent, but not excessive, lubrication is
essential for optimum functioning. Oil injected
from an oil mist lubricator will lubricate the internal
parts continuously. Use a lubricant for pneumatic
tools, Mobil Velocite #10, or equivalent. Use no
cleaning oil or additives, as these lubricants can
cause accelerated wear of seals and edges in the
appliance, resulting in a poor performance and
frequent maintenance of the tool.