Basic functions 0 (see Table 4.11a for settings)
4.2
Parameters
1: Door and gate
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
2: Barrier
The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.
3: Quiescent current The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.
4: Direction logic
Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 2 to 1. Both loops must be
activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have re-
turned to a non-activated condition for another direction detection.
0: Loop 2
Loop 2 can be deactivated in a 2-loop device.
Relay response to malfunctions (see chapter 6 Troubleshooting):
A malfunction causes
1.Door/gate
the output relay to be
released. The alarm
systems
relay drops out.
Time functions 1 , time unit 2 and time factor 3 (Einstellungen siehe Tabelle 4.11a)
4.3
The relay picks up when the
loop is activated and drops
out when the loop is exited.
Activation pulse:
The relay picks up when the
loop is activated and drops
out again after the time t.
Sensitivity 4 (see Table 4.11a for settings)
4.4
The sensitivity 5 (=Sensitivity) of the loop detector can be adapted in 9 stages: 51 = Lowest sensitivity, 59 = Highest sensitivity,
54 = Factory setting.
Automatic Sensitivity Boost ASB 5 (see Table 4.11a for settings)
4.5
ASB (=Automatic Sensitivity Boost). ASB is required in order to be able to recognise trailer drawbars after activation.
Frequency 6 (see Table 4.11a for settings)
4.6
Four different frequencies F1, F2, F3, F4* can be set in order to avoid interference when using several loop detectors.
4.7
Direction logic7 (see Table 4.11a for settings)
The direction logic function can only be used with a 2-loop device. Direction logic must have been set in the basic function (see chapter 4.2). Detection
can be performed from: ➝ Loop 1 to loop 2 ➝ From loop 2 to loop 1 ➝ from both directions
Output 2 8 (see Table 4.11b for settings)
4.8
In a device with 2 outputs, output 2 can be either activated or deactivated. In ProLoop 11, output 2 can also be set as an alarm output.
Protection against power failure 9 (see Table 4.11a for settings)
4.9
Note: The set parameter values are retained after a power failure, independent from the "Protection against power failure" function.
P 1 = Protection against power failure activated: The sensitivity is restricted to 1–5.
4.9.1
Signal characteristics with protection against power failure active (Function 9 = 1)
For Activation (e.g. Barriers)
Basic function 0 = 2 Barrier systems
Output
open (no)
closed (nc)
For Safeguarding (e.g. Barriers, bollards)
Basic function 0 = 3 Quiescent current
Output
open (no)
closed (nc)
Changeover from operation to configuration mode
4.10
1- loop device
Display after start-up:
Touch the «Mode» button once
1
to change to configuration
mode
2- loop device
Display after start-up:
Touch the «Mode» button once
1
2
to change to configuration
mode
A malfunction causes
the output relay to pick
2. Barrier
up. The alarm relay
drops out.
On delay:
The relay picks up after the
Loop
time t when the loop is acti-
Relay
vated and drops out when
the loop is exited.
Impulse by leaving the loop:
Loop
By leaving the loop,
the relay picks up after
Relay
t t
the time t, relay drops out.
Without power
Initialisation
Without power
Initialisation
A malfunction causes
3. Quiescent
the output relay to be
released. The alarm
current
relay drops out.
Loop
t t
Relay
Loop
Relay
t t
Free
Free
Mode
1
Sim1
Mode
1
Loop 1 is
Sim1
selected
A malfunction causes
4. Direction logic
the output relays to be
(2-loop device
released. The alarm
only)
relay drops out.
Off delay:
The relay picks up when the
loop is activated and drops
out after the time t when the
loop is exited.
Max. presence:
he relay picks up when the
loop is activated and drops
out again after leaving, but
at least after the time t.
Occupied
Occupied
Mode
2
Loop 2 is
Sim1
selected
*factory settings
Loop
Relay
t t
Loop
Relay
t t
Free
Free