• Press the
(17, 21) button to set the fan speed. Press the
speed from low to high and medium speed. The corresponding indicator lamps light up on
the control panel.
• Press the
(16, 26) button to set to fan mode. Press the
in the following order:
→ Normal
(manually select fan speed)
→ Natural
(alternating fan speed)
→ Night
(fan speed reduces after some time)
• During operation, press the
(15, 25) button to activate the timer function. Press the
button to set the time in one-hour intervals as follows:
1 → 2 → 3 → 4 → 5 → 6 → 7 → off → 1
The device turns off automatically after the set time runs down.
• Regularly check the water level during operation using the water level indicator (2).
• Press the
button to turn off the air cooler. Unplug the mains plug from the mains outlet
when the product is not in use. The mains cable can be rolled up using the cord wrap (8) to
save space.

Troubleshooting

Problem
Cause
Device does not
• The
button was not
turn on.
pressed.
• Mains plug not connected to
a mains outlet.
• Filter element incorrectly
inserted.
Air flow is reduced.
• Multicell filter blocked.
• Air supply otherwise blocked.

Cleaning and care

• Under no circumstances use aggressive cleanings agents, cleaning alcohol or other chemical
solutions since these can penetrate the housing or impair functionality.
• Switch off the product and disconnect the mains plug from the wall socket before cleaning.
• Wait approx. 10 minutes before removing the filter. The filters are moist and may drip water
onto the floor.
• Remove the multicell filter element (7) as illustrated below.
Remove the multicell filter element from the air cooler
• Remove the water tank and the water tank filter (12).
• Wash all parts with water and a little dishwashing liquid. The multicell filter should come into
brief contact with water only. You can also use a brush to remove filth where necessary.
• Let all parts dry sufficiently. Then reassemble all the parts in the reverse order.
• There is a safety switch around the multicell filter element. If the multicell filter element is not
inserted or if it is inserted incorrectly, the device does not turn on.
• Use a dry dust cloth to regularly wipe down the air cooler.
• Never insert fingers, writing utensils or other object through the air vents to remove filth.
• Change the water in the water tank regularly. Stagnant water may cause unpleasant odors,
in particular in warm weather.
• When not using the product for a longer period of time, cover it and store it at a dry location
protected from direct sunlight.
button to switch the fan
button to switch the fan mode
Solution
• Press the
button to turn on
the device.
• Make sure the mains plug is
connected to a mains outlet.
• Make sure the multicell filter is
attached correctly.
• Clean the multicell filter.
• Remove the blockage.
Remove the multicell filter from the filter holder
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
Remove any inserted batteries and dispose of them separately from the product.
b) Batteries
You as the end user are required by law (Battery Ordinance) to return all used
batteries. Disposing of them in the household waste is prohibited.
Contaminated batteries are labeled with this symbol to indicate that disposal in the
domestic waste is forbidden. The designations for the heavy metals involved are: Cd
= Cadmium, Hg = Mercury, Pb = Lead (name on batteries, e.g. below the trash icon
on the left).
Used batteries can be returned to collection points in your municipality, our stores or wherever
batteries are sold.
You thus fulfill your statutory obligations and contribute to the protection of the environment.
Technical data
a) Product
Operating voltage ......................... 220 – 240 V/AC, 50 Hz
Power consumption ...................... 55 W
Protection class ............................ II
Oscillation range ........................... approx. 120 °
Timer function ............................... 1 to 7 hours (one-hour interval)
Cable length ................................. approx. 1.8 m
Airflow ........................................... approx. 1311 m³/h
Speed settings .............................. 3
Water tank capacity ...................... 6 L
Multicell filter material ................... kraft paper
Operating/storage conditions ........ 0 to +45 °C, 0 – 80 % RH
Dimensions (W x H x D) ............... 260 x 675 x 275 mm
Weight .......................................... approx. 6.5 kg
b) Remote control
Battery operation .......................... 1 x 3 V battery, type CR2032
Range ........................................... 6 m
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represents the technical status at the time of printing.
Copyright 2017 by Conrad Electronic SE.
*1516852_V4_0817_02_hk_m_en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis