NOTE:
The lead-in wire should not be laid directly parallel to other power supply- and low voltage
wires.

4.3 Relay

The device is equipped with an relay (normally open contact). The connection is executed via the
connectors [NO] and [COM].

4.4 Digital inputs (IN1 / IN2)

The digital inputs [IN1] and [IN2] can only be connected to internal GND (terminal [GND]) accord-
ing to Fig. 8 connection of the digital inputs
Any connection to external voltage might damage the unit!

4.5 RS232 Interface (ID RW02.10-AD)

Readers with RS232 interface have to be connected to the host according to Fig. 9 connection of
the RS232-interface
FEIG ELECTRONIC GmbH
Installation
IN1
IN2
GND
Fig. 8 connection of the digital inputs
Host
RxD
TxD
GND
Fig. 9 connection of the RS232-interface