(6) A Current
Range
Resolution
6.000 A
0.001 A
DC
10.00 A
0.01 A
DC
6.000 A
0.001 A
AC
10.00 A
0.01 A
AC
Maximum measurement Current: 20 A
Maximum measurement time:
>5 A for max.3 minutes with at least 20 minutes rest time.
>10 A for max.30 seconds with at least 10 minutes rest time.
AC Frequency Response: 45 ~ 1 kHz (Sine Wave)
Overload Protection: AC/DC 11 A
(7) Peak Hold:
Specified accuracy ± 150 digits for < 6000 counts.
Specified accuracy ± 250 digits for >= 6000 counts
(8)Resistance
Range
Resolution
600.0 Ω
6.000 KΩ
0.001 KΩ
60.00 KΩ
600.0 KΩ
6.000 MΩ
0.001 MΩ
40.00 MΩ*
0.01 MΩ
*There is a little rolling less than ±50 digits when measuring > 10.00 MΩ.
Overload Protection: AC/DC 1000 V
(9) Continuity
Range
Resolution
600.0Ω
0.1Ω
Continuity: Built-in buzzer sounds when measured resistance is less than 20 Ω and sounds
off when measured resistance is more than 200 Ω, Between 20 Ω to 200 Ω the buzzer
maybe sound or off either.
Continuity Indicator: 2 KHz Tone Buzzer
Response Time of Buzzer: < 500 μsec.
Overload Protection: AC/DC 1000 V
RND 355-00002 AC+DC TRUE RMS INDUSTRIAL MULTIMETER — USER MANUAL
Accuracy
± (0.8% + 3d)
± (0.8% + 3d)
± (1.2% + 3d)
± (1.2% + 3d)
Accuracy
0.1 Ω
± (0.8% + 5d)
± (0.8% + 2d)
0.01 KΩ
± (0.8% + 2d)
0.1 KΩ
± (0.8% + 2d)
± (0.8% + 2d)
± (1.5% + 5d)
Accuracy
± (0.8% + 5d)
19