Herunterladen Inhalt Inhalt Diese Seite drucken

General Specifications - Rnd 355-00002 Bedienungsanleitung

Ac+dc rms industrie-multimeter
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

Specifications

General Specifications

Maximum voltage applied to any terminal: 1000 V
Display: 6000 counts.
Polarity Indication: Automatic, positive implied, negative indicated.
Overrange Indication: OL
Batteries Life: 200hours ALKALINE Battery (No Backlight)
Low Batteries Indication: Voltage drops below operating voltage,  will flash.
Power Requirement: 9V battery
Auto Power Off: 20 minutes.
Operating Temperature: -10 ~10°C
Storage Temperature:
-20°C to 60°C, 0 to 80% R.H. (batteries not fitted)
Temperature Coefficient:
0.15 x (Spec.Accy) / °C, < 18°C or > 28°C .
Measure: Samples 3 times per second .
Altitude: 6561.7 ft (2000m)
Safety: Complies with EN61010
CAT.IV. 600V, CAT.III. 1000V
CAT
Application field
I
The circuits not connected to mains.
II
The circuits directly connected to Low-voltage installation.
III
The building installation.
IV
The source of the Low-voltage installation.
Weight: 460g (including battery)
Dimensions (W x H x D): 94mm x 190mm x 48mm with holster.
Accessories: Battery (installed), Test leads and user manual.
(The probe assembly provided with the product are for use with this product)
Pollution degree: 2
16
10°C ~ 30°C (≤80% RH),
30°C ~ 40°C (≤75% RH),
40°C ~ 50°C (≤45%RH)
rms or 1000 V
rms
ac
dc.
Inhaltsverzeichnis
loading

Inhaltsverzeichnis