SPECIFICATIONS

Capacity
Input voltage
Output voltage
Output wave form
Output frequency
Battery rating
Backup time
Noise level
Operating temperature
Humidity
Dimensions
Weight
TEST THE UPS
To test UPS on battery back-up, switch off utility supply and observe "backup indicator" lights. Also
your PC should continue to function normally.
1. Self-testing while switching on.
Before turning on the UPS, the red /yellow/green led will be bright twice by turns. Then the UPS
will be ready for operation.
2. Silence function
In Battery Mode, shortly press the switch will enable or disable the buzzer. But when UPS is low
battery or overloaded, the buzzer can not be silenced.
3. Overload protection
When UPS is overloaded while operating, which is not solved by the user in time, it will cut off the
EN
output automatically after some time, then turn back to operation mode.
4. Low battery shut off
When the battery is about to be exhausted, UPS will shut down automatically to protect battery's
life.
5 Switching off
• AC normal
UPS will cut off the output and goes to AC standby mode by pressing the switch for 3 seconds.
• Backup
Press the switch for 3 seconds, the UPS will be turned off after a long beep.
16
Owner's manual
600VA
145V AC ~ 290V AC
195V AC ~ 255V AC
Stepped wave during the b/up mode
50Hz
12V / 7.2Ah
10-15 minutes
< 45 dB
0~45
C
0
10~90% non condensing
310x92x140 mm
4.37 kg