1.
Basics
The redox-potential or oxydation/reduction potential (ORP) is an electrical value which is a
parameter for the oxydation and reduction processes in the aquarium.
The redox-potential is of special interest in:
Assessing the quality of sea water in aquariums. The ideal range is between 300 mV and 400
-
mV. If needed, the range can be increased by injecting Ozone into the protein skimmer. The
higher the value, the higher the percentage of oxydation, the „cleaner" the water.
The redox-potential is used in denitrifying filters to check the acidity. The ideal values are
-
between -300 mV and -100 mV.
In swimming pools the redox-potential can be used for sterilization by regulating the amount of
-
chlorine added by maintaining +700 mV.
2.
Features
Aqua Medic Computers are micro-processor controlled units. They are safe, reliable and meet all
requirements of professional measuring and regulating devices.
The Aqua Medic mV-Computer is supplied with a redox probe and standard solution. The ozonizer
(not included) can be connected to the female side of the main power plug.
Technical Data
Micro-processor controlled
Line voltage:
Output relay-controlled:
Measurement range:
Adjustment range:
Adjustments:
Hysteresis:
Adjustment directions
adjustable:
Redox probe:
Data memory:
230 V/50 Hz
5 A, 1,000 W
- 1,999 up to + 1,999 mV
- 1,000 up to + 1,000 mV
on/off
adjustable
- upwards, with Ozone filtration mV-value may increase
- downwards by adding reducuing substances
Plastic shaft (Polysulfon)
(power loss protection)