Herunterladen Diese Seite drucken

xprgroup INOX99 Handbuch Seite 5

Werbung

UK
PROGRAMMING FLOWCHART
Assign a
User Code
Press (0)
+
Memory position from 01 to 99
Keypad
Proximity
Reader
Reader
Present Card/Tag
before the Reader*
Notes
Memory Position for User Code is always 2 digits
* no need to validate with A
Assign Examples
Ex.1: To assign User Code "12345" at Memory Position "5" and Relay in Latch Mode assuming Master Code = 000
Press 000B + 0 + 05 + 12345 + A + 3 + 05 + 1 + A + 1 + 00 + A + B.
Ex. 2: To assign User Code "6789" at Memory Position "6" and Transistor that activates for 5 seconds assuming Master Code = 000
Press 000B + 0 + 06 + 6789 + A + 3 + 06 + 2 + A + 2 + 05 + A + B.
See: Assign a User code
above
www.xprgroup.com
Enter "Master Code" OR "000" (if first time use)
1 small beep + 1 long beep + Yellow LED is 'ON'
Change
Assign Output
Master code
Press (0)
+
Memory position from
Memory
(01 to 99)
position (00)
Press (1) for Relay
Press (2) for Transistor
Press (12) for both
Enter new code
(1 to 8 digits)
See: Assign Output
above
Start
Validate by pressing (B)
NO
Validation OK?
Yellow LED blinks rapidly
YES
Set Output Timer
Press (3)
+
Pulsed Mode (01 to 99 sec):
Relay (2A):
Press (1) + (from 01 to 99)
+
Transistor:
OR
Press (2) + (from 01 to 99)
OR
OR
Latch Mode (ON/OFF):
Press (1) or (2) + (00)
Press A to validate
Validation
NO
OK?
YES
NO
Quit
programming
YES
Press B (Yellow LED is 'OFF')
End
See: Set Output Timer
5
Multiple small beeps
+
Delete Single
Code
Press (9)
+
Memory position from
(01 to 99)
above
Delete All Codes
Press (8)
+
(99)
INOX99

Werbung

loading

Verwandte Produkte für xprgroup INOX99