Validierungsbericht BSC624-12V-B
4.6
HV-Spannung als Funkti-
on der LV-Spannung
HV-voltage as a function
of the LV-voltage
4.6.1
Testaufbau
Test setup
BSC624-12V-B_Validation report_110406.docx
MM1, MM6: Metrahit 23S 16A
unfused
A
A
A
1)
MM2
V
AUX-Supply, CAN and
1)
MM5
RS232 connected via
A
testbox
Brusa-No. 149
AUX-Supply and CAN connected
via testbox
(connection via RS232 not necessary)
Brusa-No. 145
EA-PS 9750-25
Brusa-No. 397
750V/25A/9kW
Power Supply
AUX-Supply and CAN connected
via testbox
(connection via RS232 not necessary)
96 / 161
MM4: Metrahit 29S
mV
LV+
Shunt: 60mV/200A
BSC624-12V-B
(1mV/5A tap)
1)
MM3
No. 007
V
HV
Device Under Test
LV- (Housing)
Control Interface
LV+
BSC624-12V-B
No. 002
HV
Auxiliary Device
LV- (Housing)
Control Interface
LV+
1)
Valid meters:
BSC624-12V-B
- Metrahit 23S, 28S, 29S
- Agilent U1253A
No. 003
HV
Meters:
Auxiliary Device 2
- Metrahit 23S:
- Metrahit 29S:
LV- (Housing)
- Agilent U1253A:
Control Interface
Validation report BSC624-12V-B
Brusa-No.:
004, 332
401, 404
528, 537, 539,
541, 542, 544