8.

Troubleshooting

WARNING
Risk of cutting due to broken glass, metal
Risk of cutting due to broken glass, metal
or other sharp edged materials!
or other sharp edged materials!
When emptying the sweeping container,
When emptying the sweeping container,
cutting injuries may occur due to broken glass,
cutting injuries may occur due to broken glass,
metal or other sharp edged materials.
metal or other sharp edged materials.
• Wear the prescribed personal protective
• Wear the prescribed personal protective
equipment!
equipment!
CAUTION
Health impairments caused by dust
Health impairments caused by dust
resulting from sweeping!
resulting from sweeping!
The inhalation of dusts can endanger the
The inhalation of dusts can endanger the
health.
health.
• Wear the prescribed personal protective
• Wear the prescribed personal protective
equipment!
equipment!
CAUTION
Risk of injury through tipping over of the
Risk of injury through tipping over of the
sliding bracket!
sliding bracket!
Tipping over of the sliding bracket may lead to
Tipping over of the sliding bracket may lead to
slight injuries, such as jamming of the fi nger or
slight injuries, such as jamming of the fi nger or
haematomas in users or other persons.
haematomas in users or other persons.
• When carrying the device, hold it so that the
• When carrying the device, hold it so that the
sliding bracket cannot tip over.
sliding bracket cannot tip over.
Faults may occur even if the prescribed
maintenance work and checks of the device
before use are complied with. Possible faults are
listed in the table below, with specifi cation of the
cause and remedy.
haaga 375
haaga 477 / 497 Profi

8.1 Fault table

Fault
Cause
Device is
contaminated
Broom blocked
Contaminated
broom drives
Device is
running with
diffi culty or
Height
roughly
adjustment
is set too
low, contact
pressure of the
plate brooms
too high
Plate brooms do
not rotate
Bristles are
Improper
bent
storage
Sweeping
Sweeping lip is
result is
missing, loose
insuffi cient
or worn
Troubleshooting
Remedy
Clean device, see
Section 9.5
Remove blockage see
Section 9.3 "Remove
blockage"
Clean broom drives,
see Section 9.5 "Clean
device"
Set height adjustment,
see Section 7.2 in the
section "Adjust height of
plate brooms"
Contact Service
Align the bristles, see
Chapter 9.4 in the
section "Align bristles"
Replace sweeping lip
EN