CAUTION - This or any aquarium heater must never be operated out of water. Before removing
from water, unplug and allow 30 minutes for the heater to cool. Always unplug the heater during
water changes or maintenance.
Heater performance variables
Heater performance is always affected by variables such as lower room temperature, wide temperature
fluctuations, the presence of pumps and filters, or aquarium placement in proximity to cooling sources.
If the set temperature is not reached in all conditions, it may be necessary to increase the heating power.
We recommend monitoring aquarium temperature on a regular basis using an accurate thermometer such
as a Marina Aquarium Thermometer.
3. STRIP-LIGHT(S) START-UP
WARNING: The line cord Switch and the Light Timer on the Strip-Light are not safety
switches, as they NEVER cut the power off the unit. Before any installation or maintenance
operation, disconnect the plug from the electrical supply.
LINE CORD SWITCH
Depending on the specific version supplied, Fluval Aquarium Strip-Lights can be switched on and off by
either the line cord Switch or the built-in electronic Light Timer on top of the Strip Light.
Setting the Automatic Light Timer
(if included)
¡
IMPORTANT: The Light Timer does not require a battery to work since
it uses the main power supply. In case the Strip-Light is disconnected
from the power supply or in case of power failure, the internal clock of
the Light-Timer will stop. As a consequence, if the automatic On/Off
times are set, both times will be delayed by the same time as the dura-
tion of the power shortage. If required, set On and Off times once again
after resetting the system.
¡
Venezia 350 features 2 Strip-Lights with 2 independent Light Timers. As a consequence, the
On/Off time will differ according to the different programming time and/or different settings.
Before proceeding, plug the power cord of the Strip-Light into an electrical outlet.
Manual Operation of the Lights
By pressing the On/Off button once, the lights can be switched on and off manually. The lights can also
be switched on and off manually when the automatic On/Off times are set.
LIGHT TIMER
24
Automatic Operation of the Lights
The Light Timer can be switched on and off automatically after setting the On and Off times as per the
following instructions.
Be sure the setting sequence "On time" first and "Off time"
¡
second is followed and that both On and Off times are set. In
case of doubt, reset the Timer by keeping +1h button
pressed for at least 5 seconds until the LED light switches off
and restart the operation.
Setting On time
1. Reset the system by keeping +1h button pressed for at least
5 seconds until the LED light switches off.
2. Verify that the lights are off
3. Press On/Off button and keep it pressed. The lamps will
immediately come on and after a few seconds the LED light
will come on as well. Do not release the On/Off button now.
If no other button is pressed, the Light Timer will acquire the present time as the time at which the
lamps will switch on every day (for example 12:00). If you wish to delay the On time, press +1h
button for every hour that you want to add to the present time (refer to the example below: if the
+1h button is pressed 3 times, the On time will be 12:00 + 3h = 15:00). The LED will flash once every
time the +1h button is pressed and released.
4. Now release the On/Off button to let the Timer save the On time. The LED will flash for
5 seconds to confirm that the On time has been set.
Be sure the setting sequence is correct and that both On and Off times are eventually set
Line Cord Switch Light Timer
The Timer saves the On time only after the On/Off button is released. If for any reason the On/Off
¡
button is released before the desired On time has been set, restart the procedure from point #1
above.
¡
The On time setting has no effect if the Off time is not set as well.
5. Proceed with "Setting Off time".
Setting Off time
1. Verify that the lights are on.
2. Press the On/Off button and keep it pressed. The lights will immediately switch off and after a few
seconds the LED light will come on. Do not release the On/Off button now. At this point, press
+1h button for every hour that you want the Aquarium lights to stay on (refer to the example
below: by pressing +1h button 8 times, the Off time will be 15:00 + 8h = 23:00).
The LED will flash every time the +1h button is pressed and released.
3. Release the On/Off button to let the Timer save the Off time. The LED will flash 5 seconds to
confirm that the Off time has been set.
The Timer saves the Off time only when the On/Off button is released. If for any reason the On/Off
button is released before the desired Off time has been set, restart the procedure from point #1
¡
above.
How to verify that On and Off times have been set
Switch the lights on manually by pressing the On/Off button once. If the automatic On time is set, the
LED will flash for 5 seconds. If the LED does not light up, the On time is not set.
Switch the lights Off manually by pressing the On/Off button once. If the Off time is set, the LED will flash
for 5 seconds. If the LED does not light up, the Off time is not set.