Herunterladen Inhalt Inhalt Diese Seite drucken

Zanussi ZHC590 Bedienungsanleitung Seite 18

Dunstabzugshaube
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53
Ducting Connection
Connect the ducting chosen to:
• the Ø150mm ducting spigot on top of the motor
housing, or the Ø150-120mm ducting spigot item 9
and secure using the jubilee clips item 25.
• A Ø120-125mm collar item 9a is provided to fi t over
the Ø120mm ducting spigot when 125mm ducting is
fi tted.
If the room where the cooker hood is to be used
contains a fuel burning appliance such as a central
heating boiler, then its fl ue must be of the room
sealed or balanced fl ue type.
If other types of fl ue or appliances are fi tted sure
that there is an adequate supply of air to the
room.
The cooker ducting (extraction mode) must never
be connected to central heating fl ues, radiators or
water heaters etc.
Recirculation
The cooker hood is supplied specifi ed for use in the
recirculation mode, with the charcoal fi lter fi tted.
In the recirculation mode contaminated air is passed
through the charcoal fi lter to be purifi ed and recirculated
into the kitchen through the grille outlets on either side
of the chimney.
Recirculation Connection
• Insert reducer fl ange 9 on the extractor outlet.
• Push fi t connector 15 onto the reducer fl ange.
• Insert extension piece 14.2 sideways into connector
15 making sure that the outlet corresponds with the
mouth of the chimney
GB
INSTALLING THE COOKER HOOD
9 + 9a
ø 150
ø 125
18

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis