Installation and connection of the device

Connecting the appliance

All electrical work should be carried out by a suitably qualified and authorized elec-
!
trician. No alterations or willful changes in the electricity supply should be carried
out.
The voltage and the supply frequency are showed on the rating plate. The cabling and wiring system
!
must be able to bear the maximum electric power required by the oven. This is indicated on the specifi-
cations plate. If you are in any doubt at all, please contact the manufacturer-supplier services
agent or similar qualified personal.
The socket shall be connected according to the relevant standard or connected to a single-pole cutout
3.0 minimum supply.

Connection diagram

Caution! Voltage of heating elements 230V.
Caution! ln the event of any connection
the earth wire must be connected to the PE
terminal.
1
For 220–240V AC, one-phase connection,
bridges connect 1-2-3 terminals and 4-5
terminals, the earth wire from hob to PE.
2
For 220–240V AC, two-phase connection, bridges
connect1, 2-3 terminals and 4-5 terminals, the
earth wire from hob to PE.
3
For 220–240V AC, three-phased connection,
bridges connect 4-5 terminals, phases in
succession 1,2 and 3,earth to 4-5,the earth
wire to from hob to PE.
L1, L2, L3 = Phase, N = Neutral, PE = Earth
Recommended
type of connec-
tion lead
3 G 6.0 mm²
4 G 6.0 mm²