Tips & notes
• Ensure the barcode to be read is clean.
• The barcode to be read has to be fully visible.
• Keep the tilt angle and distance.
• Hold the reader horizontally to the barcode.
• Check the reader settings each time when turning it on to avoid incorrect results.
Settings
The barcode scanner can be set to your application area. The barcodes required for this can
be found in the additional quick instructions included in delivery.
Read the relevant barcodes with the barcode scanner to adjust the settings accordingly.
Resetting scanner:
The scanner can be reset to standard settings by scanning the "Default" barcode.
Two audio signals will sound.
Symbologies:
In standard settings, all symbologies are activated. You can deactivate them
individually.
Summary: settings
When the setting has been confirmed, an audio signal sounds.
Setting
Output
OUTPUT MODE - KEYBOARD/USB
Reading
SINGLE SCAN
SINGLE SCAN NO TRIGGER &
LASER TIMEOUT - 5 SECONDS
SINGLE SCAN NO TRIGGER &
LASER TIMEOUT - 2 SECONDS
Verification
CODE 11, 39, 93, 128, I2OF5,
ID2OF5, MSI, UPC/EAN
DOUBLE CHECK - ENABLE /
DISABLE (ENABLE = function on;
DISABLE = function off)
Image
REVERSE IMAGE – ENABLE /
DISABLE (ENABLE = function on;
DISABLE = function off)
Code ID
SEND BAR CODE ID - DISABLE
SEND BAR CODE ID - RESET
SEND BAR CODE ID - AS A
PREFIX
SEND BAR CODE ID - AS A
SUFFIX
Keyboard language setting (country language setting)
Setting keyboard language (for alphanumeric barcodes, such as Code 128):
DENMARK, FINLAND, FRANCE, GERMANY, ITALY, LATIN AMERICA, NETHERLANDS,
NORWAY, POLAND, SPAIN, SWITZERLAND (FRENCH), SWITZERLAND (GERMAN),
SWEDEN, UNITED KINGDOM, UNIVERSAL, UNITED STATES (USA)
Symbologies on/off [ 1 ]
CODE 11 - ENABLE / DISABLE
(ENABLE = function on; DISABLE =
function off)
CODE 39 - ENABLE / DISABLE
FULL ASCII - ENABLE / DISABLE
CODE 93 - ENABLE / DISABLE
CODE 128 - ENABLE / DISABLE
CODE 128 ISBT - ENABLE /
DISABLE
CODABAR - ENABLE / DISABLE
Symbologies on/off [ 2 ]
I2OF5 - ENABLE / DISABLE
ID2OF5 - ENABLE / DISABLE
Function
Transfer via USB
Single read, laser turns off after reading.
Press release button. Laser stays on for 5 seconds
and then turns off after reading.
Press release button. Laser stays on for 2 seconds
and then turns off after reading.
Scanner reads barcode twice, with automatic
comparison. With a matching result, it will be
transferred to the computer.
With standard settings, reads black-on-white
barcodes.
This function activates the reading of white-on-
black barcodes.
Turns transmission of barcode ID off.
Reset barcode ID.
Adds barcode ID as a prefix.
Adds barcode ID as a suffix.
Activate/deactivate symbology CODE 11.
Activate/deactivate symbology CODE 39.
Activate/deactivate symbology FULL ASCII.
Activate/deactivate symbology CODE 93.
Activate/deactivate symbology CODE 128.
Activate/deactivate symbology CODE 128 ISBT.
Activate/deactivate symbology CODABAR.
Activate/deactivate symbology I2OF5.
Activate/deactivate symbology ID2OF5.
MSI - ENABLE / DISABLE
UPC-A ENABLE / DISABLE
UPC-E ENABLE / DISABLE
EAN-13 ENABLE / DISABLE
EAN-8 ENABLE / DISABLE
Care and cleaning
• Disconnect the product from the power supply before cleaning.
• The product requires no servicing on your part aside from occasional cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Clean the product with a dry, fiber-free cloth.
• Do not scratch the safety glass of the reader (4).
• Do not immerse the product in water.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product according to
the relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
Technical data
Supply voltage .............................. 5 V/DC via USB 2.0/3.0
Current consumption .................... 65 mA
Laser class ................................... Class 1
Wavelength ................................... 650 nm
Scan speed ................................... 100 scans / second
Depth of field ................................ 500 mm (X dimension: 40/1000")
Scanning angle ............................. 38°
Ambient light ................................. max. 30000 lux (natural light)
Required contrast ......................... 45 % (between thrust face and barcode)
Symbologies ................................. UPC / EAN / JAN, Codabar, Code 11, Code 39, Code 93,
Code 128, MSI, I2OF5, ID2OF5
Operating conditions ..................... 0 to +50 °C, 10 – 85 % RH (non-condensing)
Storage conditions ........................ -20 to +60 °C, 5 – 95 % RH (non-condensing)
System requirements .................... Windows
only 32 bit, Vista™ (32 / 64 bit), 7 (32 / 64 bit), 8, 8 Pro,
Enterprise, RT, Mac OS X 10.8.2 (Mountain Lion)
Dimensions (W x H x D) ............... 60 x 160 x 90 mm
Weight .......................................... approx. 110 g (without USB cable)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in
part, is prohibited. This publication represent the technical status at the time of printing.
Copyright 2018 by Conrad Electronic SE.
Activate/deactivate symbology MSI.
Activate/deactivate symbology UPC-A.
Activate/deactivate symbology UPC-E.
Activate/deactivate symbology EAN-13.
Activate/deactivate symbology EAN-8.