STEP NINE
Wrap the Draw Band (Part B5) around the motor
housing and position so that the back of the Draw
Band touches the marks drawn in Step Five. There is
no front or back to the Draw Band itself - it is revers-
ible. Orient the arm of the Draw Band so it aligns
with the cord clamp on the cage of the motor housing
and is parallel to the Angle Brackets attached in Step
Eight. Secure using a 1/4" x 1" Stainless Steel Bolt
and a 1/4" Lock Nut. (See photo in next column)
STEP TEN
Attach the Angle Bracket on the motor to the Angle
Bracket on the Float using two 1/4" x 1/2" Bolts and
two 1/4" Lock Nuts (one set for each Bracket). See
photos for orientation based on model size. Also, the
cord clamp on the cage should be oriented toward the
Float.
Angle towards back
2400 & 3400
STEP ELEVEN
Attach the Draw Band on the motor to the Adjustment
Bracket on the Float using a 1/4" x 1/2" Bolt and a
1/4" Lock Nut. Select one of the fi ve possible posi-
tions to mount the Draw Band for your preferred
direction of fl ow. We do not recommend the two outer
(most upward and most downward) mounting posi-
tions for 8400 models.
Horizontal
Angled Up
Angle Towards front
4400 & 8400, 2.3
Angled Down
STEP TWELVE
Attach the Ropes to the front (on the cage) and back
(around the Draw Band) of the motor. At this time,
use the Nylon Tie provided to connect the power cord
and front Rope to prevent the cord from tangling in the
prop. Also, if the power cord has a Quick Disconnect
and Additional Strain Relief install the Quick Discon-
nect and Strain Relief per instructions.
STEP THIRTEEN
Float the circulator in the water and position where
desired. Tie the front Rope to a stake on the shore or
weight. If a weight is used sink weight in front of unit
so rope is taught. (Circulators create great force, make
sure weight is enough to prevent movement.) Tie back
Rope to a stake on opposite shore or weight. Sink
weight behind the unit so rope is taught. At this time
take up any slack in the line.
STEP FOURTEEN
The unit can now be connected to the electrical circuit
(fi xed wiring) with a plug or direct wire connection.
The circuit must be provided with a disconnect switch,
short circuit, and ground fault protection (RCD).
Refer to unit specs for voltage and amperage ratings.
Also, the motor name plate lists the unit's electrical
ratings. Electrical installation must follow local and
national electrical codes and should be installed by a
professional.