15

TROUBLESHOOTING

Troubles
1.Fan not works
properly
2.No indicating on
the front panel
3.Over heating light on
4.Wire feeder not
work
6.Welding Voltage
and welding current not adjustable
HOLZMANN Maschinen Austria
Cause
1.the fan line lose
2.Fan breakage
1.phase absent of the power
2.the fuse broken
3.Indicating light broken
1.aeration is not good
2.The temperature is too high
3.over-load use
4.Thermostat broken
5.Control plate broken
1.the fuse broken
2.the cables are not connected
properly
3.the wire blocked
4.the drive circuit broken
5.other reasons
1.Voltage switch line fall down
2. Voltage switch broken
3.fuse broken
4.the cables not connectecl
properly
www.holzmann-maschinen.at
TROUBLESHOOTING
Remedy
1.Connect the line
2.Change the fan
1.Check the power
2.Change the fuse 15A/250V(back
panel)
3.Change it(φ8)
1.get rid of the bar 0.5m around
2.Reduce the temperature
3.Reduce the use loading
4.Change the thermostat(JUC-OF)
5.Check and change the control
plate
1.Change the fuse 15A/250V
(on back panel)
2.check the cables
3.Check the gun
4.Change the control panel
5.Contact with the namufacturer
1.Connect the lines
2.Change it
3.Change the fuse15A/250V(on
back panel)
4.Check it
Schweißgerät/ welding machine MSA250