Maintenance and Care
The product does not require any maintenance and should never be opened or disassembled
for any reason.
Remove connected consumer loads from the radio controlled socket and remove it from the
mains socket, before cleaning the product.
Only clean the product with a soft, clean, dry cloth. Do not use aggressive cleaning agents or
chemical solutions, since these might damage the housing or impair operation.
Handling
• The radio controlled mains socket with the item no. 64 04 77 is suitable for outdoor
use (IP44). The radio controlled mains socket with the item no. 64 04 72 is only
intended for use in dry indoor locations.
• Avoid the following unfavourable environmental conditions at the installation loca-
tion and during transportation:
- Direct sunlight
- Extreme cold or heat
- Dust or fl ammable gases, fumes or solvents
- Strong vibrations
- Strong magnetic fi elds such as those found in the vicinity of machinery or louds-
peakers
• Ensure that the insulation for the entire product is neither damaged nor destroyed.
Never disassemble the product! There are no serviceable parts inside.
• Check the product for damage before each use!
If you notice any damage, do not use the product any longer!
There is a risk of a life-threatening electric shock!
Safe operation must be presumed to be no longer possible:
- if the device is visibly damaged
- if the device no longer works
- if the device was stored under unfavourable conditions for a long period of time
- if it was exposed to extraordinary stress caused by transport

Transmission range

The transmission range of the radio signals between the hand-held radio transmitter and the
radio controlled sockets is up to 30 m under optimum conditions.
This value, however, is the so-called „open space range" (range the transmit-
ter and receiver are visible to each other, without interfering infl uences).
In practical operation, however, there are walls, ceilings of rooms etc. between
the transmitter and the receiver, which reduce the range accordingly.
Due to the different infl uences on the radio transmission, no specifi c range
can be guaranteed.
However, trouble-free operation is usually possible in a detached house.
The range can sometimes be limited considerably by:
• walls, reinforced concrete ceilings
• coated/metallised insulated glass
• proximity to metal & conducting objects (e.g. radiators)
• proximity to human bodies
• Broadband interferences, e.g. in residential areas (DECT telephones, mobile phones, radio-
controlled headphones, radio-controlled speakers, radio-controlled weather stations, baby
phones etc.)
• Proximity to electric motors, transformers, power-supply units, computers
• The proximity to improperly shielded or uncovered operating computers or other electric ap-
pliances
Disposal
Dispose of the product at the end of its service life in accordance with the applicable
statutory regulations.
Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that the
product conforms to the fundamental requirements and the other relevant regulations of Di-
rective 1999/5/EC.
You can fi nd the declaration of conformity at www.conrad.com.
Technical Data
a) Radio controlled mains socket, item no. 64 04 77
Reception frequency: ................... 433 MHz
Operating voltage: ....................... 230 V/AC, 50 Hz
Protection class: .......................... I
Protection type: ............................ IP44
Connected power: ....................... 2000 W Ohm resistive load, 300 W inductive load
Address codes: ............................ 4 (selectable by turn switch)
Switching channels: ..................... Selectable with turn switch „1 2 3 4"
LED: ............................................. Lights up, when the mains socket/consumer load is activated
Dimensions (H x W x D): ............. approx. 107 x 54 x 87 mm (including connecting plug)
.....................................................
approx. 107 x 54 x 41 mm (not including connection plug)
b) Radio controlled mains socket, item no. 64 04 72
Reception frequency: ....................433 MHz
Operating voltage: ........................230 V/AC, 50 Hz
Protection class: ...........................I
Connected power: ........................2000 W Ohm resistive load, 300 W inductive load
Address codes: .............................4 (adjustable by turn switch)
Switching channels: ......................Selectable with turn switch „1 2 3 4"
LED: ..............................................Lights up, when the mains socket/consumer load is activated
Dimensions (H x W x D): ..............approx. 95 x 51 x 73 mm (including connecting plug)
......................................................approx. 95 x 51 x 35 mm (not including connection plug)
Operating environment: ................Only suitable for enclosed, dry indoor locations
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2012 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis