Herunterladen Inhalt Inhalt Diese Seite drucken

Connection / Connectors - Lake People DAC C460 Bedienungsanleitung

2-ch digital-analog converter / 2-ch digital-analog converter with headphone amplifier
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection / Connectors for analog and digital signals
DIGITAL SIGNALS
XLR MALE PLUG
HOT
COLD
SHIELD
BALANCED INCOMING SIGNAL
DIGITAL SIGNALS
XLR MALE PLUG
HOT
GND
SHIELD
BALANCED INCOMING SIGNAL
2-wire cable should be prefered !!
DIGITAL SIGNALS
CINCH/BNC PLUG
HOT
GND
SHIELD
UNBALANCED INCOMING SIGNAL
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
COLD
SHIELD
BALANCED OUTGOING SIGNAL
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
GND
SHIELD
BALANCED OUTGOING SIGNAL
2-wire cable should be prefered !!
ANALOG SIGNALS
XLR FEMALE PLUG
HOT
GND
SHIELD
BALANCED OUTGOING SIGNAL
2-wire cable should be prefered !!
Balanced Cable (Signal) to Transformer Balanced Input
Shield = Signal Ground = Pin 1
2
1
Hot / + Phase = Pin 2
Cold / - Phase = Pin 3
3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
X
to earth potential (PE) when plugged into the
corresponding socket of the case !
Unbalanced Cable (Signal) to Transformer Balanced Input
Shield = Signal Ground = Pin 1
2
1
Hot / Signal = Pin 2
Cold / Ground = Pin 3
3
The case of the connector should not be wired
?
to the shield of the cable. The connector is routed
X
to earth potential (PE) when plugged into the
corresponding socket of the case !
Unbalanced Input / Output to Unbalanced Cable
(Transformer) Balanced Output to Balanced Cable
Shield = Signal Ground = Pin 1
2
1
Hot / + Phase = Pin 2
Cold / - Phase = Pin 3
3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
X
to earth potential (PE) when plugged into the
corresponding socket of the case !
Transformer Balanced Output to Unbalanced Cable
Shield = Signal Ground = Pin 1
2
1
Hot / Signal = Pin 2
Cold / Ground = Pin 3
3
The case of the connector should not be wired
?
to the shield of the cable. The connector is routed
X
to earth potential (PE) when plugged into the
corresponding socket of the case !
Electronically Balanced Output to Unbalanced Cable
Shield = Signal Ground = Pin 1
2
1
Hot / Signal = Pin 2
(Cold) = Pin 3 = must be left open !!
3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
X
to earth potential (PE) when plugged into the
corresponding socket of the case !
9
CINCH/BNC PLUG
HOT
GND
SHIELD
UNBALANCED OUTGOING SIGNAL

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dac c460-h