Inhaltszusammenfassung für PSsystec SMARTbox IO

  • Seite 2 (Typ freiwählbar) Feuchte Drucksensoren Temperatur Strom Schaltkontakte 0...20mA 0...10V Türkontakte NTC10K | ST50 | -50°C – 105°C 0...50A 4...20mA 4...20mA Flusswaechter NTC20K | ST100 | -50°C – 105°C 0...100A Ratiometrisch 0.5..4.5V Frequency Input PT100| ST200| -200°C – 600°C 0...200A Ratiometrisch 0...5V PT1000| -200°C – 600°C Fuellstandssensor CU50 | -50°C – 105°C CU100| -50°C – 105°C PSsystec SMARTbox IO Agent User Guide...
  • Seite 3 10 x Universal inputs (NTC, PT100, PT1000, 0..10V, DIN) 1 x RelayOutput MQTT Agent for T-Systems- Cloud der Dinge For further information: please refer to the datasheet provided by PSsystec https://www.pssystec.de/downloads/ For installing the agent and SW releases, pls refer to: http://www.pssystec.de/smartbox/smartbox-agent/ For getting the device pls contact Telekom Hardware support or Pssystec Kontakt@pssystec-gmbh.de...
  • Seite 4: Connect The Smartbox To Your Cloud Der Dinge Account

    IMEI as an ID. The IMEI is printed on the devices itself: After accepting the device (this process may take 30 seconds) you should be able to see it in the All Devices list after a short delay PSsystec SMARTbox IO Agent User Guide...
  • Seite 5: Configuration

    Jumper must be set on the Smartbox for NTC and different Jumpersetting for 0..20mA (during production) It creates and measurement The settings are as follows: 0 – disabled 1 – NTC 2 – 0…20mA PSsystec SMARTbox IO Agent User Guide...
  • Seite 6: Use The Built-In Ios

    Modbus RTU (Master) Cloud Baudrate 4800, 9600, 19200, 38400, 115200 (Change during Runtime possible) Modbus Tab Parity Even, ODD, NONE (Change during Runtime possible) Modbus Tab Stopbits 2,1 (Change during Runtime possible) Modbus Tab PSsystec SMARTbox IO Agent User Guide...
  • Seite 7 Modbus devices are polled for changes. The transmit rate is the frequency where measurements are sent to CoT. g. Click "Save changes" if you made changes. PSsystec SMARTbox IO Agent User Guide...
  • Seite 8 3. Activate a regular identification of the location. In Configuration tab you can set: c8y.LocationCycle=60; define in min, how often the location should be checked. 0 means the cycled checking is disabled. If a value >0 ist set, also the tracking is enabled PSsystec SMARTbox IO Agent User Guide...
  • Seite 9 Depending on the type of device and the integration into CoT, you can also configure device-side geo-fencing and motion detection. Additionally, when the feature is activated, Cell ID information can be used to determine the position of the device. Currently, the services from Combain and Google are PSsystec SMARTbox IO Agent User Guide...
  • Seite 10 You can send AT commands in the respective language of the device and view the results of the commands. You can sent any At Command. Check here in Chapter “supported AT commands”: https://www.pssystec.de/downloads/. Frequently used commands are available by clicking the "Get predefined" button...
  • Seite 11 Local Debug and operate the device ____________ Install the Telit USB driver on your PC: https://www.pssystec.de/downloads/. The PC will recognize 6 new USB Ports For debug service: Open an Terminal program 2. Connect your PC on Telit High Speed Modem USB Port with USB port on the Smartbox 3.
  • Seite 12 PSsystec SMARTbox IO Agent User Guide...
  • Seite 13 PSsystec SMARTbox IO Agent User Guide...