7.
Error message
Error message
Display of "Err H2O" on the digital display instruments of the INVERTIG.PRO
Cause:
Insufficient throughput of coolant
8.
Technical data
TIG – COOL CART 2000
Mains voltage
Power consumption
Maximum cooling performance (air 20°C / 2.3l/min)
Feed rate maximum
Pump pressure maximum
Coolant content
Protection class
Dimension ( L x W x H )
Weight (with coolant)
TIG – COOL CART 1400
Mains voltage
Power consumption
Maximum cooling performance (air 20°C / 2.3l/min)
Feed rate maximum
Pump pressure maximum
Coolant content
Protection class
Dimension ( L x W x H )
Weight (with coolant)
9.
Correct disposal
Only applies to countries in the EU.
Do not put electrical tools in the household rubbish.
The European directive 2002/96/EG regarding the disposal of electronic an
electrical goods and the implementation of such in national law means that
used electrical tools must be collected separately and sent for
environmentally-friendly recycling.
Solution:
Switch off the system immediately
Check the connections of the water-cooled
torch
Check the water level in the tank
400 V~
1.5 A
2000 W
2.3 l/min.
0.38 MPa (3.8 bar)
5.0 l
IP 23
1050 x 600 x 880 mm
65,5 kg
400 V~
1.0 A
1400 W
2.3 l/min.
0.38 MPa (3.8 bar)
5.0 l
IP 23
1050 x 600 x 880 mm
65,5 kg