Initial Commissioning
1.
Select MENU > Status > Network on the device to record the IP address that was
assigned to the device by the DHCP server.
2.
Enter the device's IP address in the browser.
3.
Enter "admin" as the User name and also as the Password.
4.
In the Configuration Manager, select the System tab and then select Preferences >
Language. Select the required language from the list under WEBUI Language and
Phone Language.
5.
Select SIP Account Management > Account 1 > Enable Account.
6.
Enter the Internal number assigned to this device on the PBX in the entry field under
User Identifier and Authentication Name.
7.
Then enter the password assigned to this internal phone number on the PBX under
Authentication Password.
8.
In the entry field under SIP Server and Registrar enter the IP address for the PBX and
then select Save.