Set-up menu
The set-up menu looks as followed:
TMP
= 25.5 C
RH
= 32 %
BOX
= 90% Auto
CO2
= 539 ppm
Push the PTB once.
An arrow (=>) appears on the display in front of
the temperature value.
Line 1: The current temperature.
Line 2: The current humidity level.
Line 3: The current fan speed and the current
state of the fan control ("Auto" or "Man").
Line 4: The current CO2 concentration.
Adjusting setpoint
Push the PTB once. An arrow will appear on
the display (=>) in front of the TMP set.
Push the PTB again. A blinking square (■)
appears in front of TMP set.
Set the desired temperature by means of the
PTB.
Confi rm your selection by pushing the PTB or
wait several seconds for automatic
confi rmation.
Adjusting hysteresis (BANDWITH)
Push the PTB once. An arrow (=>) will appear
on the display in front of TMP set.
Place the arrow in front of TMP +/- by rotating
the PTB. Push once to confi rm.
A blinking square (■) appears in front of
TMP +/-.
Set the desired temperature hysteresis
(advise: - 0.5 to + 5.0) by means of the PTB.
Confi rm your selection by pushing the PTB or
wait several seconds for automatic
confi rmation.
TMP menu:
TMP set
26 C
TMP +/-
1.5 C
TMP Corr. +0.4
>>NEXT>>
TMP menu page 2:
TMP night 21 C
Overtemp 35c
NightDel 5 m
>>NEXT>>
Line 1: Set the desired night temperature
Line 2: The temperature at which the alarm
contact will activate. For example, in case of box
failure or inability to extract, this feature will
intervene.
Line 3: Delay period between the light turning off
and the night temperature being enforced.
In this period the fan will not speed up.
Line 4: >>NEXT>>
TMP min-max menu:
TMP
Min
21 C
TMP
Max
35 C
Reset
Min/Max
<<BACK<<
Pushing the PTB or waiting a few seconds returns
you to the set-up menu.
Adjusting Offset
Altough the temperature sensor is very accurate
it may be desired to level the indication with other
measuring equipment. Use "TMP Corr." to level
the indication with + or - 5.0 Celsius.
TMP set
26 C
TMP +/-
1.5 C
TMP Corr. +0.4
>>NEXT>>