Disconnect from the mains before any servicing.
Service only by qualified technician.
MAINTENANCE
ASPHERIC LENS & REFLECTOR.
- Disconnect from the mains.
- Unscrew the four screws 1 and unplug the Earth
link 2 then remove the lamp house bonnet 3 .
- Unlock 4 and remove the aspheric holder 5
and the reflector holder 6 .
- Clean the lenses 7 and the reflector 8 with a soft dry cloth.
- Remount all in reverse order.
- Clean in the same way the lenses in the lens tube.
CAUTION : DO NOT TOUCH THE INNER AND OUTER PART OF THE
MIRROR WITH BARE HANDS.
SPARK-GAP.
- Disconnect from the mains.
- Open the lamp house bonnet.
- Check the distance of the electrodes that should be 1mm.
(If you notice a larger gap, then please contact the ROBERT JULIAT's
technical department).
CHANGING THE COLOUR FRAMES AND COLOURS.
- Remove the colour frame from the slot 1 .
- For changing a colour, open the 4 clips 2 .
- Cut out a colour 3 : Ø 207 mm.
- For a longer gel life, it is recommended to place the darker colours
towards the front of the followspot and the I.R. filter
.
(set to Cold Beam)
robert juliat
Route de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.fr